Preliminary study for fully digitally guided implant treatment with narrow implants in the anterior region
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The aim of this study was to evaluate the survival rates of narrow implants placed in the maxillary or mandibular anterior region with digitally guided flapless surgery and prosthetic system. Thirty-five narrow implants were placed in the narrow anterior region in 20 patients using the digitally guided flapless surgery. The study subjects were divided into the immediate-loading group and the delayed-loading group. In 3 months, when the alveolar bone was healed, an oral scanner was used to produce zirconia prosthesis, and the final prosthesis was designed with a three-dimensional program. The degree of bone resorption around the implant was recorded at 12 months and 24 months after surgery. The implant fixation stability was measured after placement; the stability was in the range of Implant stability quotient (ISQ) 63–78 (average ISQ, 71.20±3.80). The radiographs obtained at 12 months and 24 months after implantation revealed that the bone around the implant in the fresh extraction socket and around the implant placed in the healed site showed an average bone resorption of 0.33±0.07 mm and 0.18±0.02 mm, respectively. After 2 weeks, one implant was removed because the patient complained of pain with radiolucency in the entire fixture. The overall implant survival rate was 97.1%. Narrow implants placed on the fresh extraction socket or healed site using the digitally guided surgery system were maintained well, with minor marginal bone resorption. As a result, we found that this method is useful for treating anterior teeth on a narrow bone.
Abstract
The aim of this study was to evaluate the survival rates of narrow implants placed in the maxillary or mandibular anterior region with digitally guided flapless surgery and prosthetic system. Thirty-five narrow implants were placed in the narrow anterior region in 20 patients using the digitally guided flapless surgery. The study subjects were divided into the immediate-loading group and the delayed-loading group. In 3 months, when the alveolar bone was healed, an oral scanner was used to produce zirconia prosthesis, and the final prosthesis was designed with a three-dimensional program. The degree of bone resorption around the implant was recorded at 12 months and 24 months after surgery. The implant fixation stability was measured after placement; the stability was in the range of Implant stability quotient (ISQ) 63–78 (average ISQ, 71.20±3.80). The radiographs obtained at 12 months and 24 months after implantation revealed that the bone around the implant in the fresh extraction socket and around the implant placed in the healed site showed an average bone resorption of 0.33±0.07 mm and 0.18±0.02 mm, respectively. After 2 weeks, one implant was removed because the patient complained of pain with radiolucency in the entire fixture. The overall implant survival rate was 97.1%. Narrow implants placed on the fresh extraction socket or healed site using the digitally guided surgery system were maintained well, with minor marginal bone resorption. As a result, we found that this method is useful for treating anterior teeth on a narrow bone.
참고문헌 (19)
- Yang G, "Risk factors and reoperative survival rate of failed narrow-diameter implants in the maxillary anterior region", Clin Implant Dent Relat Res, 22, pp.29~41 (2020)[DOI]
- Mohammed Alrabiah, "Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up", Journal of Periodontal & Implant Science, 50(2), pp.97~105 (2020), 대한치주과학회[DOI]
- Neto TH, "A comparative analysis of implants presenting different diameters: extra-narrow, narrow and conventional", Materials (Basel), 13, pp.1888~ (2020)[DOI]
- Jung RE, "Computer technology applications in surgical implant dentistry : a systematic review", Int J Oral Maxillofac Implants, 24(Suppl), pp.92~109 (2009)[DOI]
- You TM, "Morphogenesis of the peri-implant mucosa : a comparison between flap and flapless procedures in the canine mandible", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 107, pp.66~70 (2009)[DOI]
- Fang Y, "Accuracy of computerguided implant placement in anterior regions", J Prosthet Dent, 121, pp.836~842 (2019)[DOI]
- Allum SR, "The impact of loads on standard diameter, small diameter and mini implants : a comparative laboratory study", Clin Oral Implants Res, 19, pp.553~559 (2008)[DOI]
- Schiegnitz E, "Narrow-diameter implants : a systematic review and meta-analysis", Clin Oral Implants Res, 29, pp.21~40 (2018)[DOI]
- Zinsli B, "Clinical evaluation of small-diameter ITI implants : a prospective study", Int J Oral Maxillofac Implants, 19, pp.92~99 (2004)
- Trbakovic A, "A clinical and radiological long-term follow-up study of narrow diameter implants in the aesthetic area", Clin Implant Dent Relat Res, 20, pp.598~605 (2018)[DOI]
- Peron C, "Immediate provisionalization of single narrow implants in fresh extraction sockets and healed sites : clinical and radiographic outcomes of 2 years followup", Int J Periodontics Restorative Dent, 40, pp.417~424 (2020)[DOI]
- Botticelli D, "The jumping distance revisited : an experimental study in the dog", Clin Oral Implants Res, 14, pp.35~42 (2003)[DOI]
- Han CH, "Immediate loading of tapered implants placed in postextraction sockets and healed sites", J Craniofac Surg, 27, pp.1220~1227 (2016)[DOI]
- Zhou W, "Clinical factors affecting the accuracy of guided implant surgery-a systematic review and meta-analysis", J Evid Based Dent Pract, 18, pp.28~40 (2018)[DOI]
- Bover-Ramos F, "Accuracy of implant placement with computer-guided surgery : a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies", Int J Oral Maxillofac Implants, 33, pp.101~115 (2018)[DOI]
- Tahmaseb A, "Computer technology applications in surgical implant dentistry : a systematic review", Int J Oral Maxillofac Implants, 29(Suppl), pp.25~42 (2014)[DOI]
- Lin CC, "Fully digital workflow for planning static guided implant surgery : a prospective accuracy study", J Clin Med, 9, pp.980~ (2020)[DOI]
- El Kholy K, "The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery", Clin Implant Dent Relat Res, 21, pp.101~107 (2019)[DOI]
- Romeo E, "Clinical and radiographic evaluation of smalldiameter (3.3-mm) implants followed for 1-7 years: a longitudinal study", Clin Oral Implants Res, 17, pp.139~148 (2006)[DOI]