교정용 탄성 체인의 물성 비교
Comparison of physical characteristics of elastomeric chains
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
The purpose of this study was to investigate the effect of extension speed on load-deflection characteristics of elastomeric chains, and stress relaxation of elastomeric chains during uninterrupted extension of 4 weeks. Gray and transparent elastomeric chains from Ormco, 3M Unitek, RMO were tested. For load-deflection test, elastomeric chains were extended 10 mm (102% to 105% extension) with two extension speed of 10 mm/sec and 0.1 mm/sec. For stress relaxation test, the elastomeric chains were extended 10 mm and maintained on the force gauge for 4 weeks. When the extension speed was lowered to 0.1 mm/sec, forces during both extension and unloading decreased significantly, and the permanent deformation increased significantly. The initial force of elastomeric chains decreased 23% to 48% during initial 12 hours of constant extension, and then decreased 8% to 11% more during the rest of 4 week period. After 4 week of constant extension, the remaining force was 67% (transparent), 69% (gray) in RMO chains, 60% in Ormco chains, 41% (gray) to 50% (transparent) in Unitek chains. Stress relaxation of elastomeric chain seems to start at the start of extension procedure thus lowering the force level of elastomeric chain when extended more slowly, and it is recommended to determine initial force level of elastomeric chain considering the stress relaxation pattern revealed in this study.
Abstract
The purpose of this study was to investigate the effect of extension speed on load-deflection characteristics of elastomeric chains, and stress relaxation of elastomeric chains during uninterrupted extension of 4 weeks. Gray and transparent elastomeric chains from Ormco, 3M Unitek, RMO were tested. For load-deflection test, elastomeric chains were extended 10 mm (102% to 105% extension) with two extension speed of 10 mm/sec and 0.1 mm/sec. For stress relaxation test, the elastomeric chains were extended 10 mm and maintained on the force gauge for 4 weeks. When the extension speed was lowered to 0.1 mm/sec, forces during both extension and unloading decreased significantly, and the permanent deformation increased significantly. The initial force of elastomeric chains decreased 23% to 48% during initial 12 hours of constant extension, and then decreased 8% to 11% more during the rest of 4 week period. After 4 week of constant extension, the remaining force was 67% (transparent), 69% (gray) in RMO chains, 60% in Ormco chains, 41% (gray) to 50% (transparent) in Unitek chains. Stress relaxation of elastomeric chain seems to start at the start of extension procedure thus lowering the force level of elastomeric chain when extended more slowly, and it is recommended to determine initial force level of elastomeric chain considering the stress relaxation pattern revealed in this study.
참고문헌 (27)
- Andreasen GF, "Comparison of alastik chains with elastics involved with intra-arch molar to molar forces", Angle Orthod, 40, pp.151~158 (1970)
- Ash JL, "Relaxation of orthodontic elastomeric chains and modules in vitro and in vivo", J Dent Res, 57, pp.685~690 (1978)
- Baty DL, "Force delivery properties of colored elastomeric modules", Am J Orthod Dentofacial Orthop, 106, pp.40~46 (1994)
- Billmeyer FW, "Textbook of polymer science" (1984), John Wiley & Sons
- Chang HF, "Effects of instantaneous prestretching on force degradation characteristics of orthodontic plastic modules", Proc Natl Sci Counc Repub China B, 11, pp.45~53 (1987)
- De Genova DC, "Force degradation of orthodontic elastomeric chains--a product comparison study", Am J Orthod, 87, pp.377~384 (1985)
- Eliades T, "Tensile properties of orthodontic elastomeric chains", Eur J Orthod, 26, pp.157~162 (2004)
- Eliades T, "Elastomeric ligatures and chains" (2001), Stuttgart
- Ferriter JP, "The effect of hydrogen ion concen tration on the force-degradation rate of orthodontic polyurethane chain elastics", Am J Orthod Dentofacial Orthop, 98, pp.404~410 (1990)
- Hershey HG, "The plastic module as an orthodontic tooth-moving mechanism", Am J Orthod, 67, pp.554~562 (1975)
- Jeffries CL, "The effects of 2% alkaline glutaraldehyde solution on the elastic properties of elastomeric chain", Angle Orthod, 61, pp.25~30 (1991)
- Josell SD, "Force degradation in elastomeric chains", Semin Orthod, 3, pp.189~197 (1997)
- Kidd PD, "The use of thermoplastic polyurethane elastomers in orthodontics", J Elastomers Plast, 16(199), pp.199~205 (1984)
- Killiany DM, "Relaxation of elastomeric chains", J Clin Orthod, 19, pp.592~593 (1985)
- 김경호, "Effects of prestretching on force degradation of synthetic elastomeric chains", AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 128(4), pp.477~482, MOSBY-ELSEVIER
- Kim KH, "Physical properties of various brands of elastomeric chains", Korean J Orthod, 27, pp.943~954 (1997)
- Kovatch JS, "Loadextension- time behavior of orthodontic Alastiks", J Dent Res, 55, pp.783~786 (1976)
- Kuster R, "Laboratory and intra-oral tests of the degradation of elastic chains", Eur J Orthod, 8, pp.202~208 (1986)
- Lu TC, "Force decay of elastomeric chain--a serial study. Part II", Am J Orthod Dentofacial Orthop, 104, pp.373~377 (1993)
- Moore RJ, "Intra-oral temperature variation over 24 hours", Eur J Orthod, 21, pp.249~261 (1999)
- Nattrass C, "An investigation into the placement of force delivery systems and the initial forces applied by clinicians during space closure", Br J Orthod, 24, pp.127~131 (1997)
- Renick MR, "Studies of orthodontic elastomeric modules. Part 1: glass transition temperatures for representative pigmented products in the asreceived condition and after orthodontic use", Am J Orthod Dentofacial Orthop, 126, pp.337~343 (2004)
- Rock WP, "Wilson HJ", Br J Orthod, 12, pp.202~207 (1985)
- Stevenson JS, "Force application and decay characteristics of untreated and treated polyurethane elastomeric chains", Angle Orthod, 64, pp.455~464 (1994)
- Stevenson JS, "Structural degradation of polyurethanebased elastomeric modules", J Mater Sci Mater Med, 6, pp.377~384 (1995)
- Wong AK, "Orthodontic elastic materials", Angle Orthod, 46, pp.196~205 (1976)
- Young J, "The influence of preloading on stress relaxation of orthodontic elastic polymers", Angle Orthod, 49, pp.104~109 (1979)
