본문 바로가기
KERD
논문KCI 등재

Electromagnetic Environment of Transmission Line Based on Full Parameter Online Estimation

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

The parameters of transmission lines have an influence on the electromagnetic environment surrounding theline. This paper proposes a method based on phasor measurement unit (PMU) and supervisory control and dataacquisition (SCADA) to achieve online estimation of transmission line full parameters, such as resistance,reactance and susceptance. The proposed full parameter estimation method is compared with the traditionalmethod of estimating resistance independently based on SCADA system. Then, the electromagnetic environmentis analyzed based on the different parameter estimation methods. The example results illustrate that onlineestimation of transmission line full parameters is more accurate in the analysis of electromagnetic environment,which further confirms its necessity and significance in engineering application.

Abstract

The parameters of transmission lines have an influence on the electromagnetic environment surrounding theline. This paper proposes a method based on phasor measurement unit (PMU) and supervisory control and dataacquisition (SCADA) to achieve online estimation of transmission line full parameters, such as resistance,reactance and susceptance. The proposed full parameter estimation method is compared with the traditionalmethod of estimating resistance independently based on SCADA system. Then, the electromagnetic environmentis analyzed based on the different parameter estimation methods. The example results illustrate that onlineestimation of transmission line full parameters is more accurate in the analysis of electromagnetic environment,which further confirms its necessity and significance in engineering application.

참고문헌 (20)

  1. A. Costa, "An optimization model for power grid fortification to maximize attack immunity", International Journal of Electrical Power & Energy Systems, 99, pp.594~602 (2018)
  2. I. S. Okrainskaya, "Electromagnetic environment under over head power transmission lines 110–500 kV", Proceedings of International Symposium on Power Electronics Power Electronics, pp.796~801 (2012)
  3. E. Al-Bassam, "Assessment of electromagnetic field levels from surrounding high-tension overhead power lines for proposed land use", Environmental Monitoring and Assessment, 188 (2016)
  4. J. He, "Electromagnetic environment analysis of a software park near transmission lines", IEEE Transactions on Industry Applications, 40(4), pp.995~1002 (2004)
  5. M. Repacholi, "Concern that"EMF"magnetic fields from power lines cause cancer", Science of the Total Environment, 426, pp.454~458 (2012)
  6. I. N. Ztoupis, "Uncertainty evaluation in the measurement of power frequency electric and magnetic fields from AC overhead power lines", Radiation Protection Dosimetry, 157(1), pp.11~21 (2013)
  7. Y. Mo, "Investigating the impacts of meteorological parameters on electromagnetic environment of overhead transmission line", Progress In Electromagnetics Research, 70, pp.177~185 (2018)
  8. Y. Wang, "Research on the electromagnetic environment of 110kV six-circuit transmission line on the same tower", Proceedings of IEEE PES Innovative Smart Grid Technologies, pp.1~5 (2012)
  9. M. Sakashita, "Postcorrection of current", voltage and electromagnetic force for efficient hysteretic magnetic field analysis, 2017, pp.53(6), 1~4
  10. L. Zhao, "Measurement and analysis on electromagnetic environment of 1000kV UHV AC transmission line", Proceedings of 2012 Asia-Pacific Power and Energy Engineering Conference, pp.1~4 (2012)
  11. M. Sibanda, "Overview of the electromagnetic environment in the vicinity of HVDC transmission lines", Proceedings of 2013 Proceedings of the 10th Industrial and Commercial Use of Energy Conference, pp.1~7 (2013)
  12. Z. Siroma, "Expected electrochemical impedance responses of porous electrodes based on theoretical solutions of transmission-line models", Electrochemistry, 83(6), pp.425~433 (2015)
  13. F. Chen, "Tracking estimation of transmission line temperature based on PMU measurement", Automation of Electric Power Systems, 33(19), pp.25~29 (2009)
  14. F. Chen, "Tracking of dynamic thermal rating of transmission line based on SCADA", Automation of Electric Power Systems, 34(5), pp.81~85 (2010)
  15. J. C. Ding, "An overview of state estimation based on wide-area measurement system", Automation of Electric Power Systems, 30(7), pp.98~103 (2006)
  16. Y. Xue, "A review of wide area measurement system and wide area control system", Automation of Electric Power Systems, 31(15), pp.1~5 (2007)
  17. Y. Tohidi, "Coordination of generation and transmission development through generation transmission charges : a game theoretical approach", IEEE Transactions on Power Systems, 32(2), pp.1103~1114 (2016)
  18. C. Fang, "Studies on theory and expansion of power network state estimation", PhD, pp.2010
  19. K. Kopsidas, "Optimal demand response scheduling with real-time thermal ratings of overhead lines for improved network reliability", IEEE Transactions on Smart Grid, 8(6), pp.2813~2825 (2016)
  20. S. Ge, "Integrated analysis on reliability of power distribution network and urban road network", Proceedings of the CSEE, 36(6), pp.1568~1577 (2016)

관련 논문AI추천

이 간행물의 다른 논문 (18건)