Objectives : In this study, following the cavity restorations with low copper conventional alloy, high copper admixed one and high copper unicompositional one, which are used the most frequently in a clinical setting at the present, to experiment the time-dependent changes of strength, bubbles were examined. Besides, to examine the detrimental effects of mercury contained in dental amalgam, the amount of mercury release was evaluated. Methods : As dental amalgams which were used herein, [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy] were selected for a low-copper conventional amalgam, a high-copper admixed one and a high-copper unicompositional one in the corresponding order. The formation of bubbles and the weight ratio of mercury release were evaluated using a field emission scanning electron microscope (FE-SEM). Thus, the following results were obtained:Results :1. The time-dependent amount of mercury release reached a statistical significance in three types of alloys, which was shown in such a descending order as [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy]. 2. A low-copper conventional type, BESTALOY is a cutting type and it was found to have an increased formation of fine bubbles. In the remaining two types, [Hi-Aristaloy 21] (a high-copper admixed alloy) and [Sybraloy] (a high-copper unicompositional alloy), the time-dependent changes in the formation of bubbles was negligible. Conclusions : Accordingly, this type of mercury release from amalgam alloy denotes the difference in the weight ratio of total constituents between after 24 hours and after two weeks. But further studies are warranted to examine the amount of mercury release which is detrimental to human bodies. Besides, a low-copper conventional alloy is a cutting type and it was characterized by the abundant formation of bubbles in a time-dependent manner. This implies that the strength of amalgam is impaired, which should be considered in selecting the appropriate amalgam alloy in a clinical setting.

Abstract

Objectives : In this study, following the cavity restorations with low copper conventional alloy, high copper admixed one and high copper unicompositional one, which are used the most frequently in a clinical setting at the present, to experiment the time-dependent changes of strength, bubbles were examined. Besides, to examine the detrimental effects of mercury contained in dental amalgam, the amount of mercury release was evaluated. Methods : As dental amalgams which were used herein, [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy] were selected for a low-copper conventional amalgam, a high-copper admixed one and a high-copper unicompositional one in the corresponding order. The formation of bubbles and the weight ratio of mercury release were evaluated using a field emission scanning electron microscope (FE-SEM). Thus, the following results were obtained:Results :1. The time-dependent amount of mercury release reached a statistical significance in three types of alloys, which was shown in such a descending order as [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy]. 2. A low-copper conventional type, BESTALOY is a cutting type and it was found to have an increased formation of fine bubbles. In the remaining two types, [Hi-Aristaloy 21] (a high-copper admixed alloy) and [Sybraloy] (a high-copper unicompositional alloy), the time-dependent changes in the formation of bubbles was negligible. Conclusions : Accordingly, this type of mercury release from amalgam alloy denotes the difference in the weight ratio of total constituents between after 24 hours and after two weeks. But further studies are warranted to examine the amount of mercury release which is detrimental to human bodies. Besides, a low-copper conventional alloy is a cutting type and it was characterized by the abundant formation of bubbles in a time-dependent manner. This implies that the strength of amalgam is impaired, which should be considered in selecting the appropriate amalgam alloy in a clinical setting.

참고문헌 (24)

  1. 김경남, "치과용 수은. 1(3)판", pp.4~5 (1991), 임상치재
  2. 고영무, "치과재료학. 3판", pp.203~224 (2004), 군자출판사
  3. 이진헌, "Sodium selenite와 마늘이 有機水銀 中毒에 미치는 影響에 관한 實驗的 硏究", 석사, pp.1987
  4. Sawair FA, "Observance of proper mercury hygiene practices by Jordanian general dental practitioners", Int J Occup Med Environ Health, 23(1), pp.47~54 (2010)
  5. 김혜성, "치과의원 종사자들의 체내 수은축적과 신장기능과의 관련에 대한 연구", 석사, pp.1999
  6. 이영은, "구강보건의료전달체계의 모형에 관한 연구", 대한구강보건학회지, 7, pp.109~110 (1983)
  7. Magos L, "Mercury metabolism and toxicology: Dental amalgam-a health hazard", pp.11~32 (1991), Copen-hagen Press
  8. Larson D, "Effect of prepared cavities on the strength of teeth", Oper Dent, 6, pp.2~5 (1981)
  9. Cavel WT, "An in vivo study of cuspal fracture", J Prosthet Dent, 53, pp.38~42 (1985)
  10. Eakle WS, "Fracture of posterior teeth in adult", JADA, 112, pp.215~218 (1986)
  11. Ben-Amar A, "Marginal microleakage", Dent Mat, 2, pp.45~47 (1986)
  12. Liberman R, "Long-term sealing properties of amalgam restorations: in vitro study", Dent Mat, 5, pp.168~170 (1989)
  13. Markey MR, "Pin reinforcement and retention of amalgam foundations and restorations", JADA, 56, pp.675~679 (1958)
  14. Pashley EL, "Amalgam build-ups(shear strength and dentin sealing properties)", Oper Dent, 16, pp.82~89 (1991)
  15. 홍선기, "영천·군위 주민 혈중 수은 농도 평균의 4.4배" (2010), YTN
  16. 정일해, "아말감 충전 아동 해 없다 미국 연구팀,중추신경계 등 부작용 발견 못해", 치의신보 (2008)
  17. Barry ME, "치과용 아말감 구조와 부식", 서울대학교 치과생체재료학자료집, 36, pp.13~14 (2002)
  18. 김수철, "아말감 충전후 증발수은의 치아주의조직내 침수에 관한 연구", 대한치과의사학회지, 12(6), pp.373~375 (1974)
  19. Hanson M, "The dental amalgam issue", A review, Experientia, 47(1), pp.9~22 (2005)
  20. Chien-Ping Ju, "Effect of heat treatment on structure and properties of dispersed-type dental amalgam, Journal of materials science", Materials in medicine, 19(1), pp.83~93 (2007)
  21. Troconis CB, "Influence of thermal treatments on Ag Sn Cu powders in order to reduce mercury contents in dental amalgam, Journal of materials science", Materials in medicine, 11(1), pp.1~9 (2004)
  22. Myaki SI, "Microleakage in primary teeth restored by conventional or bonded amalgam technique", Braz Dent J, 12(3), pp.197~200 (2001)
  23. 하대송, "유구치 와동형성이 아말감 파절에 미치는 영향에 관한 연구", 대한소아치과학회지, 11(1), pp.159~167 (1884)
  24. Trester J, "Amalgam restorations", J Am Dent Assoc, 132(9), pp.1206~1208 (2001)

관련 논문AI추천

이 간행물의 다른 논문 (11건)