Objectives : The purpose of this study is to analyze the sterilizing effects of toothbrushes by administering bacteria into toothbrushes and reproducing the antibacterial effects using a microwave oven. Methods : The heads of four-row mid-strength toothbrushes were cut, put in a bacterial solution (3×109cells/ml) for vortexing, and sterilized with microwaves for 0, 30, and 60 seconds. They were then moved into four tubes containing DW 10 ml and suspended in a vortex mixer for two minutes to separate bacteria from them. DW 9ml was added by 1ml of bacteria for dilution of 10~106 times. It was then administered to the BHI agar plate by 0.1ml and cultured at 37℃ for 24 hours. Total number of bacteria adhered to a toothbrush was obtained by multiplying the number of colonies by the dilution factor. The experiment was done in the first, second, and third step, being repeated in a normal temperature drier (23℃) after 5, 9 and 24 hours. Results : The results of the experiment revealed that the sterilizing effects were 95% or over. When toothbrushes were sterilized for 60 seconds, the number of colonies is about 11 after drying for 5 hours, 7after drying for 9 hours and 2 after drying for 24 hours. The sterilizing effects reached 98% when the bacteria-administered toothbrush was sterilized for 1 minute after drying for 24 hours. Conclusions : The results demonstrated that toothbrush sterilizing by using microwave is a suitable way to prevent cross-contamination of toothbrushes by oral bacterial infection and thus easy to use at home. However, this study suggests that toothbrush sterilizing by using microwave should be limited within two times a week because the physical properties of toothbrush might be changed.
Abstract
Objectives : The purpose of this study is to analyze the sterilizing effects of toothbrushes by administering bacteria into toothbrushes and reproducing the antibacterial effects using a microwave oven. Methods : The heads of four-row mid-strength toothbrushes were cut, put in a bacterial solution (3×109cells/ml) for vortexing, and sterilized with microwaves for 0, 30, and 60 seconds. They were then moved into four tubes containing DW 10 ml and suspended in a vortex mixer for two minutes to separate bacteria from them. DW 9ml was added by 1ml of bacteria for dilution of 10~106 times. It was then administered to the BHI agar plate by 0.1ml and cultured at 37℃ for 24 hours. Total number of bacteria adhered to a toothbrush was obtained by multiplying the number of colonies by the dilution factor. The experiment was done in the first, second, and third step, being repeated in a normal temperature drier (23℃) after 5, 9 and 24 hours. Results : The results of the experiment revealed that the sterilizing effects were 95% or over. When toothbrushes were sterilized for 60 seconds, the number of colonies is about 11 after drying for 5 hours, 7after drying for 9 hours and 2 after drying for 24 hours. The sterilizing effects reached 98% when the bacteria-administered toothbrush was sterilized for 1 minute after drying for 24 hours. Conclusions : The results demonstrated that toothbrush sterilizing by using microwave is a suitable way to prevent cross-contamination of toothbrushes by oral bacterial infection and thus easy to use at home. However, this study suggests that toothbrush sterilizing by using microwave should be limited within two times a week because the physical properties of toothbrush might be changed.
참고문헌 (19)
- Paik DI, "Clinical Preventive Dentistry. Fifth Edition", pp.81~90 (2011), Komoomsa
- Lee MO, "Bacteriological contamination of toothbrushes by dental plaque acidogenicity and related behaviors to toothbrush use", J korean society of dental hygiene, 4(2), pp.255~263 (2004)
- Caudry SD, "Contaminated toothbrushes and their disinfection", J Can Dent Assoc, 61(6), pp.511~516 (1995)
- Verran J, "Investigation into the microbial contramination of toothbrushes", Microbios, 85(345), pp.231~238 (1996)
- Sang Hee An, "The measurement of toothbrush contamination", Korean Academy Of Oral Health, 20(1), pp.121~135 (1996)
- Livia Nordi Dovigo, "Microwave Disinfection of complete Dentures Contaminated In Vitro With Selected Bacteria", J Prosthodont, 18(7), pp.611~617 (2009)
- Cardoso VH, "Microwave disinfection of gauze contaminated with bacteria and fungi", Indian J Med Microbiol, 25(4), pp.428~429 (2007)
- Kim YH, "Disinfection and sterilization", pp.227~252 (1995), Korea Medical Book
- Jeong YK, "Bacteriological Contamination of Home Toothbrushes and Hygiene Improvement", Korean Academy Of Oral Health, 16(1), pp.15~17 (1992)
- Guan D, "Microbiological validation of microwave-circulated water combination heating technology by inoculated pack studies", J. Food Sci, 68(4), pp.1428~1432 (2003)
- 박강훈, "자외선 잇솔살균기의 살균효과", 대한구강보건학회지, 26(1), pp.89~100 (2002), 대한구강보건학회
- Banik S, "Bioeffects of microwave-a brief review", Bioresource Technology, 87(2), pp.155~159 (2003)
- Latimer JM, "Microwave oven irradiation as a method for bacterial decontamination in a clinical microbiology laboratory", J Clin Microbiol, 6(4), pp.340~342 (1977)
- Sherbondy AL, "Variability in catheter microwave sterilization techniques in a single clinic population", J Urol, 168(2), pp.562~564 (2002)
- Nelson-Filho P, "Efficacy of microwaves and chlorhexidine on the disinfection of pacifiers and toothbrushes: an in vitro study", Pediatr Dent, 33(1), pp.10~13 (2011)
- Ribeiro DG, "Denture disinfection by microwave irradiation: A randomized clinical study", J Dent, 37(9), pp.666~672 (2009)
- Dreyfuss MS, "Comparison of effects of sublethal microwave radiation and conventional heating on the metabolic activity of Staphylococcus aureus", Appl Environ Microbiol, 39(1), pp.13~16 (1980)
- Kozai K, "Residual contamination of toothbrushes by microorganisms", ASDC J Dent Child, 56(3), pp.201~204 (1989)
- Kim JB, "Dentists and dental patients attitudes toward oral hygiene devices selection", Korean Academy Of Oral Health, 16(2), pp.493~504 (1992)