골전도 청성지속반응 검사 재검사 신뢰도
Test-Retest Reliability of Bone-Conducted Auditory Steady-State Response
0
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Auditory steady-state response (ASSR) are used for estimating hearing sensitivity of those who cannot be subjectively tested. Recently, bone-conducted (BC) ASSR are also available on clinical systems but the test-retest reliability of BC ASSR has not been reported. The purpose of this study was to investigate the test-retest reliability of BC ASSR in adults with normal hearing and with sensorineural hearing loss (SNHL). Data were obtained from 22 ears with normal hearing and 11 ears with SNHL. The BC ASSR measurement was performed at carrier frequencies of 500, 1,000, 2,000 and 4,000 Hz using the Audera system. All procedures for measuring the BC ASSR were repeated within 15 days. There were no significant differences in BC ASSR thresholds between the test and the retest for both groups (p>.05). The correlation coefficients of the BC ASSR thresholds ranged from poor (0.34, 0.38) for 500, 1,000 Hz to moderate (0.58, 0.62) for 2,000, 4,000 Hz in normal hearing adults. The correlation coefficients in SNHL adults were 0.33, 0.90, 0.93 and 0.68 for each test frequency. Results demonstrated moderately strong reliability for 1,000, 2,000 and 4,000 Hz, although the reliability for 500 Hz was low. It is suggested, therefore, that the BC ASSR measurement be a clinically reliable test especially in high frequencies.
Abstract
Auditory steady-state response (ASSR) are used for estimating hearing sensitivity of those who cannot be subjectively tested. Recently, bone-conducted (BC) ASSR are also available on clinical systems but the test-retest reliability of BC ASSR has not been reported. The purpose of this study was to investigate the test-retest reliability of BC ASSR in adults with normal hearing and with sensorineural hearing loss (SNHL). Data were obtained from 22 ears with normal hearing and 11 ears with SNHL. The BC ASSR measurement was performed at carrier frequencies of 500, 1,000, 2,000 and 4,000 Hz using the Audera system. All procedures for measuring the BC ASSR were repeated within 15 days. There were no significant differences in BC ASSR thresholds between the test and the retest for both groups (p>.05). The correlation coefficients of the BC ASSR thresholds ranged from poor (0.34, 0.38) for 500, 1,000 Hz to moderate (0.58, 0.62) for 2,000, 4,000 Hz in normal hearing adults. The correlation coefficients in SNHL adults were 0.33, 0.90, 0.93 and 0.68 for each test frequency. Results demonstrated moderately strong reliability for 1,000, 2,000 and 4,000 Hz, although the reliability for 500 Hz was low. It is suggested, therefore, that the BC ASSR measurement be a clinically reliable test especially in high frequencies.
참고문헌 (9)
- 서유진, "정상 성인의 측정위치에 따른 골전도 청성지속반응", 석사, pp.2006
- 홍상모, "ASSR, ABR, PTA를 이용한 정상인과 전음성 난청인에서의 기골도 역치 차이 비교", Kor J Audiol., 8(2), pp.139~144 (2004)
- D’Haenens W, "Auditory steady-state responses in normal hearing adults: A test-retest reliability study", Int J Auiol, 47, pp.489~498 (2008)
- Kaf WA, "Reliability of electric response audiometry using 80 Hz auditory steady-state responses", Int J Auiol, 45, pp.477~486 (2006)
- Lins OG, "Frequency-specific audiometry using steady-state responses", Ear Hear, 17, pp.81~96 (1996)
- Luts H, "Comparison of MASTER and AUDERA for measurement of auditory steady-state responses", Int J Auiol, 44, pp.244~253 (2005)
- Roeser R, "Auditory diagnosis" (2000), Thieme
- Small SA, "Artifactual Responses When Recording Auditory Steady-State Responses", Ear Hear, 25, pp.611~623 (2004)
- Small SA, "Maturation of bone conduction multiple auditory steady-state responses", Int J Auiol., 47, pp.476~488 (2008)
