본문 바로가기
KERD
논문KCI 등재

자극제시레벨에 따른 노인의 Gaps-in-Noise 측정에 관한 연구

Gaps-in-Noise Measurement of the Elderly as a Function of Stimulus Level

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: The gaps-in-noise (GIN) test was developed as a clinical evaluation of temporal resolution. In the GIN test, a sensation level of 50 dB SL was recommended as a standard clinical presentation level to ensure stimulus audibility. It has been reported that the stimulus level less than 30 dB SL should not be used as presentation level to verify a proper level for administration of GIN test. Given that the previous finding was based on the data of young normal-hearing adults, the present study aimed to compare the GIN results as a function of stimulus level in listener groups differing in age and hearing sensitivity. Methods: Participants were 10 young normal-hearing (YNH), 12 elderly normal-hearing, and 12 elderly hearing-impaired (EHI) listeners. GIN was administered at 20, 30, 40, and 50 dB SL. The performance was determined from both the approximate threshold and the percentage of correct gap. Results: As results, both approximate threshold and percent correct in GIN results were measured. Results showed that, overall, both the threshold as well as the percent correct in GIN improved with increasing stimulus level. Across groups, EHI showed the poorest results from GIN test, with the best performance in YNH. EHI listeners with greater hearing loss at higher frequencies (2-8 kHz) were poorer at detecting gaps in noise. Across a range of stimulus level (20-50 dB SL), the GIN performance between 40 and 50 dB SL did not differ in all listener groups. Conclusion: A sensation level of 35-50 dB may be applicable to the elderly with normal hearing or slight-to-mild degree of hearing loss, without significant change in GIN performance.

Abstract

Purpose: The gaps-in-noise (GIN) test was developed as a clinical evaluation of temporal resolution. In the GIN test, a sensation level of 50 dB SL was recommended as a standard clinical presentation level to ensure stimulus audibility. It has been reported that the stimulus level less than 30 dB SL should not be used as presentation level to verify a proper level for administration of GIN test. Given that the previous finding was based on the data of young normal-hearing adults, the present study aimed to compare the GIN results as a function of stimulus level in listener groups differing in age and hearing sensitivity. Methods: Participants were 10 young normal-hearing (YNH), 12 elderly normal-hearing, and 12 elderly hearing-impaired (EHI) listeners. GIN was administered at 20, 30, 40, and 50 dB SL. The performance was determined from both the approximate threshold and the percentage of correct gap. Results: As results, both approximate threshold and percent correct in GIN results were measured. Results showed that, overall, both the threshold as well as the percent correct in GIN improved with increasing stimulus level. Across groups, EHI showed the poorest results from GIN test, with the best performance in YNH. EHI listeners with greater hearing loss at higher frequencies (2-8 kHz) were poorer at detecting gaps in noise. Across a range of stimulus level (20-50 dB SL), the GIN performance between 40 and 50 dB SL did not differ in all listener groups. Conclusion: A sensation level of 35-50 dB may be applicable to the elderly with normal hearing or slight-to-mild degree of hearing loss, without significant change in GIN performance.

참고문헌 (30)

  1. Amaral, M. I, "Temporal resolution : Performance of school-aged children in the GIN-gaps-in-noise test", Brazilian Journal of Otorhinolaryngology, 76(6), pp.745~752 (2010)
  2. 방정화, "Hearing Thresholds for a Geriatric Population Composed of Korean Males and Females", Journal of Audiology & Otology, 19(2), pp.91~96 (2015), 대한청각학회
  3. Bertoli, S, "Effects of age, age-related hearing loss, and contralateral cafeteria noise on the discrimination of small frequency changes : Psychoacoustic and electrophysiological measures", Journal of the Association for Research in Otolaryngology, 6(3), pp.207~222 (2005)
  4. 최정희, "Gap-in-Noise (GIN) 검사를 통한 한국인의 시간적 분석 능력", Audiology and Speech Research, 9(2), pp.148~156 (2013), 한국청각언어재활학회
  5. Feng, Y, "Temporal resolution in regions of normal hearing and speech perception in noise for adults with sloping high-frequency hearing loss", Ear and Hearing, 31(1), pp.115~125 (2010)
  6. Florentine, M, "Temporal gap detection in sensorineural and simulated hearing impairments", Journal of Speech and Hearing Research, 27(3), pp.449~455 (1984)
  7. Folstein, M. F, ""Mini-mental state". A practical method for grading the cognitive state of patients for the clinician", Journal of Psychiatric Research, 12(3), pp.189~198 (1975)
  8. Gelfand, S. A, "Consonant recognition in quiet and in noise with aging among normal hearing listeners", The Journal of the Acoustical Society of America, 80(6), pp.1589~1598 (1986)
  9. Grose, J. H, "Perceptual organization of sequential stimuli in listeners with cochlear hearing loss", Journal of Speech and Hearing Research, 39(6), pp.1149~1158 (1996)
  10. Hall, J. W. 3rd, "Temporal analysis and stimulus fluctuation in listeners with normal and impaired hearing", Journal of Speech, Language, and Hearing Research, 41(2), pp.340~354 (1998)
  11. Harris, K. C, "Agerelated differences in gap detection : Effects of task difficulty and cognitive ability", Hearing Research, 264(1-2), pp.21~29 (2010)
  12. Heinrich, A, "Age-related changes in within-and between-channel gap detection using sinusoidal stimuli", The Journal of the Acoustical Society of America, 119(4), pp.2316~2326 (2006)
  13. John, A. B, "Effects of advancing age and hearing loss on gaps-in-noise test performance", American Journal of Audiology, 21(2), pp.242~250 (2012)
  14. 권효은, "이명과 난청이 GIN (Gaps-In-Noise)과 이명장애지수에 미치는 영향", Audiology and Speech Research, 11(2), pp.108~119 (2015), 한국청각언어재활학회
  15. Kwon, Y. C, "Korean version of Mini-Mental State Examination(MMSE-K) : Part I. Development of the test for the elderly", Journal of Korean Neuropsychiatric Association, 28(1), pp.125~135 (1989)
  16. Marculino, C. F, "Gaps-in-noise test : Gap detection thresholds in 9-year-old normal-hearing children", Jornal da Sociedade Brasileira de Fonoaudiologia, 23(4), pp.364~367 (2011)
  17. Mazelová, J, "Auditory function in presbycusis : Peripheral vs. central changes", Experimental Gerontology, 38(1-2), pp.87~94 (2003)
  18. Moore, B. C, "Detection of temporal gaps in sinusoids by normally hearingand hearingimpaired subjects", The Journal of the Acoustical Societyof America, 85(3), pp.1266~1275 (1989)
  19. Musiek, F. E, "GIN(gaps-in-noise)test performance in subjects with confirmedcentral auditory nervous system involvement", Ear and Hearing, 26(6), pp.608~618 (2005)
  20. Ok, S. J, "The effects of ipsilateral and contralateral background noises on gap detection thresholds in the elder", Audiology, 3(1), pp.36~42 (2007)
  21. 박재경, "청년, 중년, 노년군의 시간적 청각정보 처리능력 비교: GIN (Gaps-in-noise)과 시간압축 문장인지도 측정을 중심으로", Audiology and Speech Research, 11(4), pp.310~319 (2015), 한국청각언어재활학회
  22. Prem, G, "Gaps in noise(GIN)testnormative data", American Journal of Medicine, 8(1), pp.24~27 (2012)
  23. Samelli, A. G, "The gaps-in-noise test : Gap detection thresholds in normal-hearing young adults", International Journal of Audiology, 47(5), pp.238~245 (2008)
  24. Sanches, S. G, "GIN test(gaps-in-noise)in normal listeners with andwithout tinnitus", Pró-fono, 22(3), pp.257~262 (2010)
  25. Schneider, B. A, "Gap detection thresholds as a function of tonal duration for younger and older listeners", The Journal of the Acoustical Society of America, 106(1), pp.371~380 (1999)
  26. Schneider, B. A, "Gap detection and the precedence effect in young and old adults", The Journal of the Acoustical Society of America, 95(2), pp.980~991 (1994)
  27. Shinn, J. B, "GIN(gaps-in-noise)performance in the pediatric population", Journal of the American Academy of Audiology, 20(4), pp.229~238 (2009)
  28. Snell, K. B, "Relationships among age-related differences in gap detection and word recognition", The Journal of the Acoustical Society of America, 107(3), pp.1615~1626 (2000)
  29. Takahashi, G. A, "Modulation detection, modulation masking, and speech understanding in noise in the elderly", Journal of Speech and Hearing Research, 35(6), pp.1410~1421 (1992)
  30. Weihing, J. A, "The effect of presentation level on the gaps-in-noise(GIN)test", Journal of the American Academy of Audiology, 18(2), pp.141~150 (2007)

이 간행물의 다른 논문 (6건)