키워드

초록

Purpose: Sound is localized by two ears. People with bilaterally severe-to-profound hearing loss may struggle to identify the direction of a sound if their hearing device delivers sound only one ear due to the loss of binaural advantage. The purpose of this study was to systematically investigate the sound localization performance of people with unilateral cochlear implant users. Methods: Ten unilateral cochlear implant users and 10 normal hearing adults participated in this study. Sound localization tests were conducted using five stimuli (speech, speech with noise, 500 Hz warble tone, 1 kHz warble tone, and 4 kHz warble tone) presented from eight loud-speakers. Correct responses and rootmean- square errors were obtained to investigate the localization performances and error patterns. Additional factors including the Korean-Speech Spatial and Qualities of Hearing Questionnaire were also analyzed. Results: Localization performance was significantly poor in the unilateral cochlear implant group showing polar patterns toward their hearing side. While the normal hearing group showed better localization for speech in quiet conditions compared to 500 Hz warble tone, the cochlear implant group did not show any statistical difference in performance across the stimuli due to their very poor performance. The Korean-Speech Spatial and Qualities of Hearing Questionnaire was associated with localization performance in limited conditions. Conclusion: The present study revealed that unilateral cochlear implant users correctly localize a sound at nearly chance levels. The Korean-Speech Spatial and Qualities of Hearing Questionnaire predict localization performance for unilateral cochlear implant users only for particular conditions.

Abstract

Purpose: Sound is localized by two ears. People with bilaterally severe-to-profound hearing loss may struggle to identify the direction of a sound if their hearing device delivers sound only one ear due to the loss of binaural advantage. The purpose of this study was to systematically investigate the sound localization performance of people with unilateral cochlear implant users. Methods: Ten unilateral cochlear implant users and 10 normal hearing adults participated in this study. Sound localization tests were conducted using five stimuli (speech, speech with noise, 500 Hz warble tone, 1 kHz warble tone, and 4 kHz warble tone) presented from eight loud-speakers. Correct responses and rootmean- square errors were obtained to investigate the localization performances and error patterns. Additional factors including the Korean-Speech Spatial and Qualities of Hearing Questionnaire were also analyzed. Results: Localization performance was significantly poor in the unilateral cochlear implant group showing polar patterns toward their hearing side. While the normal hearing group showed better localization for speech in quiet conditions compared to 500 Hz warble tone, the cochlear implant group did not show any statistical difference in performance across the stimuli due to their very poor performance. The Korean-Speech Spatial and Qualities of Hearing Questionnaire was associated with localization performance in limited conditions. Conclusion: The present study revealed that unilateral cochlear implant users correctly localize a sound at nearly chance levels. The Korean-Speech Spatial and Qualities of Hearing Questionnaire predict localization performance for unilateral cochlear implant users only for particular conditions.

참고문헌 (41)

  1. Alzaher, M., "Contribution of a method of assessing minimum audible angle in headphones", European Annals of Otorhinolaryngology, Head and Neck Diseases, 138(5), pp.333~336 (2021)
  2. Bagatto, M., "Consensus practice parameter : Audiological assessment and management of unilateral hearing loss in children", International Journal of Audiology, 58(12), pp.805~815 (2019)
  3. Bomhardt, R., "A high-resolution head-related transfer function and three-dimensional ear model database", Proceedings of Meetings on Acoustics, 29(1), pp.050002~ (2016)
  4. Carlile, S., "The nature and distribution of errors in sound localization by human listeners", Hearing Research, 114(1-2), pp.179~196 (1997)
  5. 최재희, "한국어 버전 일상생활 청각행동 설문지의 신뢰도와 타당도", Audiology and Speech Research, 13(1), pp.19~27 (2017), 한국청각언어재활학회
  6. Dhanasingh, A., "Bilateral cochlear implantation", Acta Oto-laryngologica, 141(sup1), pp.1~21 (2021)
  7. Dunn, C. C., "Comparison of speech recognition and localization performance in bilateral and unilateral cochlear implant users matched on duration of deafness and age at implantation", Ear and Hearing, 29(3), pp.352~359 (2008)
  8. Firszt, J. B., "Unilateral hearing loss : Understanding speech recognition and localization variabilityimplications for cochlear implant candidacy", Ear and Hearing, 38(2), pp.159~173 (2017)
  9. Gartrell, B. C., "Investigating long-term effects of cochlear implantation in single-sided deafness : A best practice model for longitudinal assessment of spatial hearing abilities and tinnitus handicap", Otology and Neurotology, 35(9), pp.1525~1532 (2014)
  10. Gatehouse, S., "The speech, spatial and qualities of hearing scale(SSQ)", International Journal of Audiology, 43(2), pp.85~99 (2004)
  11. Grieco-Calub, T. M., "Sound localization skills in children who use bilateral cochlear implants and in children with normal acoustic hearing", Ear and Hearing, 31(5), pp.645~656 (2010)
  12. Ham, H. S., "Sound localization in subjects with a unilateral hearing loss according to hearing loss", Korean Journal of Otorhinolaryngology-Head and Neck Surgery, 42(8), pp.961~966 (1999)
  13. Hartmann, W. M., "Localization of sound in rooms", The Journal of the Acoustical Society of America, 74(5), pp.1380~1391 (1983)
  14. 허지혜, "인공와우와 보청기 양이착용이 K-HINT 수행도에 미치는 혜택", Audiology and Speech Research, 5(1), pp.60~70 (2009), 한국청각언어재활학회
  15. Jang, H., "Development of Korean standard sentence lists for sentence recognition tests", Audiology and Speech Research, 4(2), pp.161~177 (2008)
  16. Johnston, J. C., "Bilateral paediatric cochlear implants : A critical review", International Journal of Audiology, 48(9), pp.601~617 (2009)
  17. 김봉직, "한국어판 The Speech, Spatial and Qualities of Hearing Scale의 표준화: 타당도 및 신뢰도 연구", 대한이비인후-두경부외과학회지, 60(6), pp.279~294 (2017), 대한이비인후과학회[DOI]
  18. 이영미, "순차적 양측 인공와우이식 청년의 기능적인 듣기 수행력", Communication Sciences and Disorders, 23(4), pp.1111~1126 (2018), 한국언어청각임상학회[DOI]
  19. Lee, S., "Predicting speech recognition using the speech intelligibility index and other variables for cochlear implant users", Journal of Speech, Language, and Hearing Research, 62(5), pp.1517~1531 (2019)
  20. Litovsky, R. Y., "Bilateral cochlear implants in children : Localization acuity measured with minimum audible angle", Ear and Hearing, 27(1), pp.43~59 (2006)
  21. Litovsky, R. Y., "Bilateral cochlear implants in adults and children", Archives of Otolaryngology-Head and Neck Surgery, 130(5), pp.648~655 (2004)
  22. Lovett, R. E., "Bilateral or unilateral cochlear implantation for deaf children : An observational study", Archives of Disease in Childhood, 95(2), pp.107~112 (2010)
  23. Luntz, M., "Sound localization in patients with unilateral cochlear implants", Cochlear Implants International, 6(1), pp.1~9 (2005)
  24. Mills, A. W., "On the minimum audible angle", The Journal of the Acoustical Society of America, 30(4), pp.237~246 (1958)
  25. Neuman, A. C., "Sound-direction identification with bilateral cochlear implants", Ear and Hearing, 28(1), pp.73~82 (2007)
  26. Nopp, P., "Sound localization in bilateral users of MED-EL COMBI 40", 40+ cochlear implants, 2004, pp.25(3), 205~214
  27. Pastore, M. T., "Head movements allow listeners bilaterally implanted with cochlear implants to resolve front-back confusions", Ear and Hearing, 39(6), pp.1224~1231 (2018)
  28. Perrott, D. R., "Minimum audible angle thresholds for sources varying in both elevation and azimuth", The Journal of the Acoustical Society of America, 87(4), pp.1728~1731 (1990)
  29. Purdy, S. C., "A parental questionnaire to evaluate children's auditory behavior in everyday life(ABEL)", American Journal of Audiology, 11(2), pp.72~82 (2002)
  30. Recanzone, G. H., "Comparison of relative and absolute sound localization ability in humans", The Journal of the Acoustical Society of America, 103(2), pp.1085~1097 (1998)
  31. Sarant, J., "Bilateral versus unilateral cochlear implants in children : A study of spoken language outcomes", Ear and Hearing, 35(4), pp.396~409 (2014)
  32. Scherf, F., "Hearing benefits of second-side cochlear implantation in two groups of children", International Journal of Pediatric Otorhinolaryngology, 71(12), pp.1855~1863 (2007)
  33. Seeber, B. U., "Localization cues with bilateral cochlear implants", The Journal of the Acoustical Society of America, 123(2), pp.1030~1042 (2008)
  34. Senn, P., "Minimum audible angle, just noticeable interaural differences and speech intelligibility with bilateral cochlear implants using clinical speech processors", Audiology and Neuro-Otology, 10(6), pp.342~352 (2005)
  35. Stevens, S. S., "On the nature of aural harmonics", Proceedings of the National Academy of Sciences of the United States of America, 22(11), pp.668~672 (1936)
  36. Strutt, J. W., "On our perception of sound direction", Philosophical Magazine, 13(74), pp.214~232 (1907)
  37. Tyler, R. S., "Speech perception and localization with adults with bilateral sequential cochlear implants", Ear and Hearing, 28(2 Suppl), pp.86S~90S (2007)[DOI]
  38. Tyler, R. S., "Three-month results with bilateral cochlear implants", Ear and Hearing, 23(1 Suppl), pp.80S~89S (2002)[DOI]
  39. van Hoesel, R. J., "Speech perception, localization, and lateralization with bilateral cochlear implants", The Journal of the Acoustical Society of America, 113(3), pp.1617~1630 (2003)
  40. Wightman, F. L., "Monaural sound localization revisited", The Journal of the Acoustical Society of America, 101(2), pp.1050~1063 (1997)
  41. Wood, K. C., "Relative sound localisation abilities in human listeners", The Journal of the Acoustical Society of America, 138(2), pp.674~686 (2015)

관련 논문AI추천

이 간행물의 다른 논문 (6건)