Assessment of bovine blood sample stability for complete blood count and blood gases and electrolytes analysis during storage
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Delayed arrival of blood samples from the field and a large number of samples delivered often causes delay in sample analysis leading to inaccurate measurements. Therefore, this study aimed to assess wheth-er prolonged storage in refrigerator could influence the stability of cattle blood samples and to establish an optimal time limit for complete blood count (CBC) parameters and blood gas and electrolyte (BGE) parameters analyses. Samples collected from healthy cows were tested immediately for CBC and BGE using automated hematology, blood gas and electrolyte analyzers. Samples were kept in refrigerator at 4°C and analyzed after 6 h, 12 h, 24 h, 48 h, 72 h, 120 h, and 192 h of storage. Mean differences be-tween observations were assessed at 5% significance level using ANOVA and Duncan’s multiple range test. Total CBC parameters and the platelet profile remained stable for 192 h, except for MCHC. Among leukocyte-related counts, NEU and EOS remained stable for 192 hours. WBC and LYM, and MONO values produced inconsistent measurements which recovered its initial measurement after 12 h and 24 h of storage, respectively, then remained stable until 120 h. Among the blood gas indices, PCO2, PO2, tCO2, and BE showed declining and significant changes over time, but pH, tHb, and SO2 remained sta-ble for 192 h. Electrolyte status in the blood showed that ions are unstable and tend to change in as early as 6 h of storage. This study established that cattle blood specimens for CBC analysis can be stored for 120 h at 4°C, but specimens for BGE analyses must be tested within 6 to 24 h.
Abstract
Delayed arrival of blood samples from the field and a large number of samples delivered often causes delay in sample analysis leading to inaccurate measurements. Therefore, this study aimed to assess wheth-er prolonged storage in refrigerator could influence the stability of cattle blood samples and to establish an optimal time limit for complete blood count (CBC) parameters and blood gas and electrolyte (BGE) parameters analyses. Samples collected from healthy cows were tested immediately for CBC and BGE using automated hematology, blood gas and electrolyte analyzers. Samples were kept in refrigerator at 4°C and analyzed after 6 h, 12 h, 24 h, 48 h, 72 h, 120 h, and 192 h of storage. Mean differences be-tween observations were assessed at 5% significance level using ANOVA and Duncan’s multiple range test. Total CBC parameters and the platelet profile remained stable for 192 h, except for MCHC. Among leukocyte-related counts, NEU and EOS remained stable for 192 hours. WBC and LYM, and MONO values produced inconsistent measurements which recovered its initial measurement after 12 h and 24 h of storage, respectively, then remained stable until 120 h. Among the blood gas indices, PCO2, PO2, tCO2, and BE showed declining and significant changes over time, but pH, tHb, and SO2 remained sta-ble for 192 h. Electrolyte status in the blood showed that ions are unstable and tend to change in as early as 6 h of storage. This study established that cattle blood specimens for CBC analysis can be stored for 120 h at 4°C, but specimens for BGE analyses must be tested within 6 to 24 h.
참고문헌 (30)
- Abd Ellah MR, "Effect of storage time and temperature on erythrocytes, platelets and leucocytes pictures of cattle and equine blood", J. Anim. Vet. Adv, 10, pp.2768~2771 (2011)[DOI]
- B.H. Anderson, "The effect of dexamethasone on some immunological parameters in cattle", Veterinary Research Communications, 23(7), pp.399~413 (1999), Springer Science and Business Media LLC[DOI]
- Peter S. Aronson, "Effects of pH on Potassium: New Explanations for Old Observations", Journal of the American Society of Nephrology, 22(11), pp.1981~1989 (2011), American Society of Nephrology (ASN)[DOI]
- JayaR Asirvatham, "Errors in potassium measurement: A laboratory perspective for the clinician", North American Journal of Medical Sciences, 5(4), pp.255~ (2013), Medknow[DOI]
- C. BRIGGS, "ICSH Guideline for worldwide point-of-care testing in haematology with special reference to the complete blood count", International Journal of Laboratory Hematology, 30(2), pp.105~116 (2008), Wiley[DOI]
- C. Briggs, "ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting", International Journal of Laboratory Hematology, 36(6), pp.613~627 (2014), Wiley[DOI]
- Sabrina Buoro, "Assessment of blood sample stability for complete blood count using the Sysmex XN-9000 and Mindray BC-6800 analyzers", Revista Brasileira de Hematologia e Hemoterapia, 38(3), pp.225~239 (2016), Elsevier BV[DOI]
- Mauro Buttarello, "Quality specification in haematology: the automated blood cell count", Clinica Chimica Acta, 346(1), pp.45~54 (2004), Elsevier BV[DOI]
- Peter Constable, "Clinicopathologic variables associated with hypokalemia in lactating dairy cows with abomasal displacement or volvulus", Journal of the American Veterinary Medical Association, 242(6), pp.826~835 (2013), American Veterinary Medical Association (AVMA)[DOI]
- Daves M, "Sample stability for complete blood cell count using the Sysmex XN haematological analyser", Blood Transfus, 13, pp.576~582 (2015)[DOI]
- Tsering Dhondup, "Acid-Base and Electrolyte Disorders in Patients with and without Chronic Kidney Disease: An Update", Kidney Diseases, 3(4), pp.136~148 (2017), S. Karger AG[DOI]
- J C Freedman, "Ionic and osmotic equilibria of human red blood cells treated with nystatin.", The Journal of General Physiology, 74(2), pp.157~185 (1979), Rockefeller University Press[DOI]
- Gurbuz Gokce, "Effect of time delay and storage temperature on blood gas and acid–base values of bovine venous blood", Research in Veterinary Science, 76(2), pp.121~127 (2004), Elsevier BV[DOI]
- D.E. Gomez, "Physicochemical Approach to Determine the Mechanism for Acid-Base Disorders in 793 Hospitalized Foals", Journal of Veterinary Internal Medicine, 29(5), pp.1395~1402 (2015), Wiley[DOI]
- Dammika Gunawardena, "Reliability of Parameters of Complete Blood Count With Different Storage Conditions", Journal of Clinical Laboratory Analysis, 31(2), pp.e22042~ (2017), Wiley[DOI]
- P. HEDBERG, "Aging stability of complete blood count and white blood cell differential parameters analyzed by Abbott CELL-DYN Sapphire hematology analyzer", International Journal of Laboratory Hematology, 31(1), pp.87~96 (2009), Wiley[DOI]
- Hussein HA, "Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood", Open Vet. J, 3, pp.1~7 (2013)
- Fatime Imeri, "Stability of hematological analytes depends on the hematology analyser used: A stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100", Clinica Chimica Acta, 397(1-2), pp.68~71 (2008), Elsevier BV[DOI]
- Meredyth L. Jones, "Evaluation of the Ruminant Complete Blood Cell Count", Veterinary Clinics of North America: Food Animal Practice, 23(3), pp.377~402 (2007), Elsevier BV[DOI]
- Lee S, "Clinical usefulness of the serum anion gap", pp.44~46 (2006), Electrolyte Blood Press
- Shiela Francisco Margallo, "Stability of complete rabbit blood count parameters in under various storage times and temperatures", Journal of Veterinary Science & Technology, 09 (2018), OMICS Publishing Group[DOI]
- C. Médaille, "Stability of selected hematology variables in canine blood kept at room temperature in EDTA for 24 and 48 hours", Veterinary Clinical Pathology, 35(1), pp.18~23 (2006), Wiley[DOI]
- Okereke Henry Nnamdi, "Stability of hematological parameters of canine blood samples stored with citrate phosphate dextrose adenine-1 anticoagulated plastic vacutainers", Veterinary World, 12(3), pp.449~453 (2019), Veterinary World[DOI]
- Radkowska I, "Hematological and biochemical blood parameters in dairy cows depending on the management system", Anim. Sci. Pap. Reports, 32, pp.317~325 (2014)
- Leonie Roland, "Hematology as a diagnostic tool in bovine medicine", Journal of Veterinary Diagnostic Investigation, 26(5), pp.592~598 (2014), SAGE Publications[DOI]
- Sattar A, "Haematological parameters in exotic cows during gestation and lactation under subtropical conditions", Pak. Vet. J, 29, pp.129~132 (2009)
- Tendulkar A, "Stability of Selected Hematological Parameters in Stored Blood Samples", Journal of Cell Science & Therapy, 06(05) (2015), OMICS Publishing Group[DOI]
- Wieth JO, "Chloride-bicarbonate exchange in red blood cells: physiology of transport and chemical modification of binding sites", Philosophical Transactions of the Royal Society of London. B, Biological Sciences, 299(1097), pp.383~399 (1997), The Royal Society[DOI]
- Dong-wen Wu, "How Long can we Store Blood Samples: A Systematic Review and Meta-Analysis", EBioMedicine, 24, pp.277~285 (2017), Elsevier BV[DOI]
- Martina Zaninotto, "Effects of sample transportation on commonly requested laboratory tests", Clinical Chemistry and Laboratory Medicine, 50(10) (2012), Walter de Gruyter GmbH[DOI]
