Non-invasive Transcutaneous pCO_2 Gas Monitoring System for Arterial Blood Gas Analysis
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide(pCO_2) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 μm in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis(TcpCO_2) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.
Abstract
Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide(pCO_2) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 μm in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis(TcpCO_2) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.
참고문헌 (23)
- Romain A. Pauwels, "Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease", Am. J. Respir. Crit. Care Med, 163(5), pp.1256~1276 (2001)
- Celli BR, "Standards for the diagnosis and care of patients with chronic obstructivepulmonary disease", Am J Respir Crit Care Med, 152, pp.77~120 (1995)
- "Chronic Obstructive Pulmonary Disease: NICE guideline No 12: National clinical guideline on management of chronic obstructive pulmonary disease in adult in primary and secondary care", Thorax, 59(suppl1), pp.S1~S232 (2004)
- 정동민, "비침습적 산소 및 이산화탄소 분압의 감시 - 경피적 산소 및 이산화탄소 분압과 호기말 이산화탄소 분압 측정의 정확도 -", 대한응급의학회지, 20(5)통권 : 5, pp.481~487 (2009), 대한응급의학회
- Hyang Yi Bang, "Characteristics of transcutaneous gas sensor based on LiF glass using soft lithography", Sensors and Materials, 19(8) (2007)
- Stock MC, "Noninvasive carbon dioxide monitoring", Crit Care Clin, 4, pp.511~526 (1988)
- G. H. Greenspan, "Transcutaneous noninvasive monitoring of carbon dioxide tension", Chest, 80, pp.442~446 (1981)
- K. K. Tremper, "Effects of hypercarbia and shock on transcutaneous carbon dioxide at different electrode temperatures", CRC Crit. Care.Med, 8, pp.608~612 (1980)
- Jacob Fraden, "Handbook of Mosern Sensors, Second Edition", pp.64~77, Thermoscan,Inc
- Bruce B. Benson, "Empirical laws for dilute aqueous solutions of nonpolar gases", J. Chem. Phys, 64(2) (1976)
- Choi Joo Hwan, "The UV-vVis & atom absorption spectroscopy", pp.57~61 (1998), Woo Yong Publishing Company
- Kwon H.Y, "Hematology Experiment" (2001), Koryo Medicine
- Seoul National University, "Breath pneumatics" (2000), Seoul National University
- John G. Webster, "Encyclopedia of medical devices and instrumentation" (1999), WILEY
- H. Ahlberg, "Industrialized high sensitivity fiber-optic near-IR diode laser based gas analysis system", Proc. SPIE, Tunable diode laser spectroscopy, lidar, and DIAL techniques for environmental and industrial measurements, 통권 : 2112, pp.118~129 (1994)
- Lysle H, "Modern concepts in medical physiology", ~ (1982)
- G.Herzberg, "Molecular spectra and molecular structure II: Infrared and raman spectra of polyatomic molecules, Reprint Edition" (1991), Krieger Kublishing Company
- Miles E. Denham, "GAS: A neglected phase in remediation of metals and radionuclides", Environmental Science & Technology (2007)
- Monaco F, "Transcutaneous measure-ment of carbon dioxide partial pressure in sick neo-nates", Crit Care Med, 9(7), pp.56~58 (1981)
- Tatevossian RG, "Transcutaneous oxygen and as early warning of tissue hypoxia and hemodynamic shock in criticallyill emergency patients", Crit Care Med, 28, pp.2248~2253 (2000)
- 한상도, "나노 결정 SnO2와 백금 박막히터를 이용한 접촉연소식 마이크로 가스센서의 감응특성 연구", 센서학회지, 17(3), pp.178~182 (2008), 한국센서학회
- Chien LC, "Hemodynamic patterns preceding circulatory deterioration and death after trauma", J Trauma, 62, pp.928~932 (2007)