본문 바로가기
KERD
논문KCI 등재

표면처리별 S10T, 10.9HRC 고장력 볼트 세트의 체결 품질 연구

The Joining Quality of High Strength Bolt, Nut and Washer Set (S10T & 10.9HRC) under the Surface Treatment Conditions

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기계공학

초록

This test focuses on the correlations between joining axial force at non-room temperature and at room temperature according to the surface treatment (Geomet, Dacro, Green Kote, Armore Galv.). The quality characteristics of the fastening axial force required by the KSB 2819 and EN14399-10 standards were discussed. Surface treatment was implemented to S10T and 10.9HRC sets of bolts under the same environmental factors. Development for the stabilization of the fastening axial force required by each standard should continually be enforced, and the fastening and storage in the field should be maintained at room temperature. Managing stabilization of torque enumerated data is required after application of surface treatment. It is concluded that, by conducting the test of applying surface treatment to effectively manage, each lot-specific rate of axial force at room temperature conditions should be maintained below the maximum 4.47%. The decline rate of axial force should be maintained under 2.15% maximum, and the standard deviation of the room temperature condition should be maintained below 0.5.

Abstract

This test focuses on the correlations between joining axial force at non-room temperature and at room temperature according to the surface treatment (Geomet, Dacro, Green Kote, Armore Galv.). The quality characteristics of the fastening axial force required by the KSB 2819 and EN14399-10 standards were discussed. Surface treatment was implemented to S10T and 10.9HRC sets of bolts under the same environmental factors. Development for the stabilization of the fastening axial force required by each standard should continually be enforced, and the fastening and storage in the field should be maintained at room temperature. Managing stabilization of torque enumerated data is required after application of surface treatment. It is concluded that, by conducting the test of applying surface treatment to effectively manage, each lot-specific rate of axial force at room temperature conditions should be maintained below the maximum 4.47%. The decline rate of axial force should be maintained under 2.15% maximum, and the standard deviation of the room temperature condition should be maintained below 0.5.

참고문헌 (9)

  1. 석한길, "극한 상태에서 A490 고장력 볼트 세트의 체결 품질 연구", 한국표면공학회지, 44(1), pp.21~25 (2011), 한국표면공학회
  2. John H. Blackford, "An Introduction to the Design and Behavior of Bolted Joints", pp.5~ (1981), Marcel Dekker Inc
  3. H. G. Suk, , Materials Science Forum, 580-582, pp.681~ (2008)
  4. H. G. Suk, , Materials Science Forum, 580-582, pp.687~ (2008)
  5. "마찰접합용 고장력 6각볼트, 6각너트, 평와셔의 세트", KS B1010, ~
  6. "마찰접합용 고력 6각볼트, 6각너트, 평와셔의 세트", JIS B1186, ~
  7. "구조용 토크-전단형 고장력 볼트, 6각너트, 평와셔의 세트", KS B2819, ~
  8. "High-strength structural bolting assemblies for preloading. Part 10: System HRC. Bolt and nut assemblies with calibrated preload", EN14399-10, ~
  9. "구조용 Torshear 형 고력 볼트, 6각 너트, 평와셔의 세트", JSS II-09, ~