본문 바로가기
KERD
논문KCI 등재

니켈쌀파메이트 전주층의 실시간 잔류응력

Real-time Internal Stress of Nickel Sulfamate Electroform

2

조회

0

다운로드

1

인용

0

참고문헌

주제분류기계공학

초록

Abstract

The control of internal stress is extremely important in electroforming because of the deliberately low adhesion between the electroform and the mandrel. Excessive tensile or compressive stress can cause distortion, separation problem, curling, peeling or separation of electroform prematurely from the mandrel, buckling and blistering. Nickel sulfamate bath has been widely used in electroforming because of its low internal stress and moderate hardness. In this study, real-time stress sensor has been used for stress control in chloride-free nickel sufamate bath for 400㎜×300㎜×500㎛ nickel electroform. It was found that compressive stress found at low current density indicated the contamination of electrolyte, which is very useful in procuring buckling and peeling of electroform. No compressive stress is allowed for plate electroform. The real-time stress can also be used for accurate stress control of nickel electroform. The tensile stress was found to be increased slightly with increase in nickel electroform thickness, i.e., from initial 1.47ksi to 2.02ksi at 320㎛.

참고문헌 (2)

  1. "The Origins of Stress in Electrodeposits", pp.137~146
  2. "Fast and Accurate Deposit Internal Stress Determination" (1998)