본문 바로가기
KERD
논문KCI 등재

Measurement of Metal-Film Removal Rate in a Microemulsion Using QCM

0

조회

0

다운로드

0

인용

0

참고문헌

주제분류기계공학

초록

Abstract

A set of Quartz Crystal Microbalances (QCM's) was used to observe the film removal characteristics of three different CO2-nitric acid microemulsions. QCM's electroplated with nickel or copper were used as specimens. F-AOT, NP-4 and the newly synthesized Proline Surfactant-1 were used as surfactants to create microemulsions. While the F-AOT microemulsion yielded a relatively low removal rate, that of the Proline Surfactant-1 completely removed the Cu metal film within a short period of time. The NP-4 microemulsion removed the metal surface. However, removal rate measurements per QCM were not possible due to the instability of the microemulsion when Cu ions were present in the nitric solution. The reaction kinetics and metal removal capabilities of microemulsions formed by the different surfactants are explained along with the characteristics of reverse micelles.

참고문헌 (8)

  1. "Supercritical Fluid Extraction Wiley-Interscience Publication" (1996)
  2. "J. of Supercritical Fluids", 259 (2000)
  3. "Supercritical Fluid Cleaning - Fundamentals, Technology and Applica- tions" (1998), Noyes Publication
  4. "Theory of Surface Active" (2000)
  5. "Journal of Colloid and Interface Science", 241 (2001)
  6. "J. of Supercritical Fluids" (2004)
  7. "Biosens and Bioelectron" (1999)
  8. "Sensors and Actuators" (2000)

관련 논문AI추천

이 간행물의 다른 논문 (8건)