용융탄산염연료전지(MCFC) 스택의 1200시간 운전 후 분리판 채널부 표면 열화 분석 및 연구
Study of Corrosion and Post Analysis for the Separator Channel of MCFC Stack after Cell Operation for 1200 hours
1
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
Of all components of MCFC(molten carbonate fuel cell), corrosion of separator is one of the most decisive factor for commercializing of MCFC. In order to provide better understanding of corrosion behavior and morphology for gas channel of separator plate, post-analysis after cell operation for 1200 hours at 650oC was performed by optical microscope, SEM and EPMA. Intergranular corrosion was observed on gas channel of separator plate. Corrosion product layer was identified as Fe-oxide, Cr-oxide and Ni-oxide by EPMA, and oxide thickness was measured with a 60mm-150mm. Also, gas channel of separator was damaged by severe intergrannular attack with post analysis in consistent with immersion test. Moreover, pitting on the channel plate was observed with a depth of 18~24mm. The results of immersion method are well agreement with post analysis measurements.
참고문헌 (7)
- "Proceedings of the 1st Symposium on MCFC 1984 Proceedings of the 2nd Symposium on MCFC Proceedings of the 3rd Symposium on MCFC Proceedings of the 4th Symposium on MCFC"
- "Program and Abstract of 1996 Fuel Cell Seminar" (1996), Orlando, Florida
- "Assessment of Research Needs for Advanced Fuel Cell", Pergamon Press Plenum Press
- "Fuel Cells and Their Applications" (1996), VCH, Weinheim, Germany
- "Principles and Prevention of Corrosion" (1992), Prentice Hall
- A, "National Association of Corrosion Engineers" (1986), in Corrosion 86
- K, "Cho et al"