에너지성능분석 및 감성평가에 의한 오피스 창호의 적정 투과율 선정
Optimal Windows Transmittance by Energy Performance Analysis and Subjective Evaluation in office building
0
조회
0
다운로드
10
인용
0
참고문헌
키워드
초록
Abstract
The purpose of this study is to select the optimal transmittance rate of windows in office buildings through subjective evaluation and energy performance analysis(computer simulation program ; DOE 2.1E).The results are as follows ; 1) In the subjective evaluation experiment, minimum transmittance of the glass is GE 30% and LT 70%, but the optimal transmittance rate is concluded in 40%~60%. 2) As a result of the energy performance analysis, it is desirable for the building of consumptive with mainly air-conditioning to make transmittance as 40-60%. 3) Comparing foreign study on minimum and optimal transmittance rate is 25%~38%, the minimum transmittance of this study is almost the same. But for the optimal transmittance rate, 20% more is needed for KOREAN.
참고문헌 (4)
- "유리창이 사무소 건물의 에너지 소비에 미치는 영향에 관한 연구" (1993)
- "건축 실내공간 색채평가를 위한 실험방법의 유효성 검증", 18(1) (2002)
- "‘사무소 건물의 냉난방에너지 소비실태조사’" (1994)
- "Lighting and energy performance of solar film coating in air-conditioned cellular offices"", pp.921~937