Abstract

The purpose of this study is to select the optimal transmittance rate of windows in office buildings through subjective evaluation and energy performance analysis(computer simulation program ; DOE 2.1E).The results are as follows ; 1) In the subjective evaluation experiment, minimum transmittance of the glass is GE 30% and LT 70%, but the optimal transmittance rate is concluded in 40%~60%. 2) As a result of the energy performance analysis, it is desirable for the building of consumptive with mainly air-conditioning to make transmittance as 40-60%. 3) Comparing foreign study on minimum and optimal transmittance rate is 25%~38%, the minimum transmittance of this study is almost the same. But for the optimal transmittance rate, 20% more is needed for KOREAN.

참고문헌 (4)

  1. "유리창이 사무소 건물의 에너지 소비에 미치는 영향에 관한 연구" (1993)
  2. "건축 실내공간 색채평가를 위한 실험방법의 유효성 검증", 18(1) (2002)
  3. "‘사무소 건물의 냉난방에너지 소비실태조사’" (1994)
  4. "Lighting and energy performance of solar film coating in air-conditioned cellular offices"", pp.921~937