공동주택에서 필로티 세대의 난방에너지 분석
The Analysis of the Heating Energyin Apartment Houses with Pilotis
0
조회
0
다운로드
5
인용
0
참고문헌
초록
Abstract
This paper presents an analysis of heating energy for apartment houses in apartment building, paying special attention on the effect of pilotis which is increasing recently. A four-zone model composed of one conditioned and three unconditioned space is developed in this study. IES VE is adopted to estimate heating energy. Especially, we used Apache module for a heating energy calculated. The predicted result shows fairly good agreements with the available measured data and simulation data. Heating energy needed for an apartment located on the pilotis floors is far greater compared with the case of intermediate floors. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. It is finally concluded that the location dependent, severe imbalance in heating energy should be improved and reflected in the policy making process and the design standards.Keywards : 에너지 평가(Energy estimation), 공동주택(Apartment houses), 난방에너지(Heating energy) IES VE기 호 설 명
참고문헌 (4)
- "The Census of Population and Residence 2000. Report of residence." (2000)
- "Survey on energy consumption according to heating methods in apartment houses", pp.622~627 (2003)
- "Analysis of Heating Energy in a Korean-Style Apartment Building 1 : The Effect of Location", 16(1), pp.101~110 (2003)
- "Report of energy consumption depending on the location and floor for apartment house", pp.91~103 (1998)