초록

The majority of fixed shading devices are installed in the exterior of a building in order to dissipate the heat absorbing from the sun and to prevent the direct sunlight. In designing external shading devices for windows, many requirements must be considered simultaneously ; solar geometry, optimum energy performance, multi-purpose usage and design factors etc.. In order to satisfy these requirements, we suggests the folding shading device and its optimum design methodology. Also we analyzed the thermal performance using the IES_VE program according to various operating modes and compared with existing shading devices. The results show that proposed device reduce about 1.90~22.40% in cooling load and about 1.09~24.22% in heating load in comparison with existing ones

Abstract

The majority of fixed shading devices are installed in the exterior of a building in order to dissipate the heat absorbing from the sun and to prevent the direct sunlight. In designing external shading devices for windows, many requirements must be considered simultaneously ; solar geometry, optimum energy performance, multi-purpose usage and design factors etc.. In order to satisfy these requirements, we suggests the folding shading device and its optimum design methodology. Also we analyzed the thermal performance using the IES_VE program according to various operating modes and compared with existing shading devices. The results show that proposed device reduce about 1.90~22.40% in cooling load and about 1.09~24.22% in heating load in comparison with existing ones

참고문헌 (9)

  1. 김자경, "자연과 함께하는 건축-환경친화적 건축개념에서 기법까지", pp.381~397 (2004), 시공문화사
  2. 최원기, "자연 에너지의 효과적인 이용을 위한 독립된 외부 차양장치의 응용", 박사, pp.2005
  3. Bansal, N. K., "Passive building design" (1994), Elsevier science B. V.
  4. A. K. Athienitis, "Thermal Analysis and Design of Passive solar Buildings", pp.84~113 (2003), James & James
  5. Helmut Köster, "Dynamic Daylighting Architecture", pp.22~23 (2004), Brikhäuser
  6. ISO, "ISO", DIS 15099, Thermal performance of windows, doors and shading devices-detailed calculations, 1999
  7. WINDOW 5 NFRC simulation manual, "THERM 5", pp.2002, LBNL
  8. 최원기, "건물의 환경성능 향상을 위한 독립형 외부 차양장치의 응용에 관한 연구", 대한건축학회논문집 계획계, 22(4), pp.293~300 (2006), 대한건축학회
  9. 최원기, "창-벽면적비 20%인 소규모 건물의 수평 차양장치의 민감도 분석", 대한건축학회논문집 계획계, 21(12), pp.321~328 (2005), 대한건축학회

관련 논문AI추천

이 간행물의 다른 논문 (9건)