본문 바로가기
KERD
논문KCI 등재

외피 열성능에 따른 건물에너지효율등급 분석 연구

A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope

0

조회

0

다운로드

6

인용

0

참고문헌

키워드

주제분류기타공학

초록

According to the building regulation U-value limitation of window is 3.3W/㎡․K in southern regions, while U-value limitation of wall is 0.35~0.58W/㎡․K. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

Abstract

According to the building regulation U-value limitation of window is 3.3W/㎡․K in southern regions, while U-value limitation of wall is 0.35~0.58W/㎡․K. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

참고문헌 (3)

  1. 박효순, "공동주택의 발코니개조가 건물에너지효율등급에 미치는 영향에 관한 연구", 대한건축학회논문집 계획계, 22(3), pp.295~302 (2006), 대한건축학회
  2. 김지연, "공동주택의 발코니 확장에 따른 열환경 성능 평가 및 개선방법에 관한 연구", 한국태양에너지학회 춘계학술발표대회 논문집, pp.67~72 (2006)
  3. 현종훈, "고유가 대응을 위한 신단열재 적용과 경제성평가 연구 : 공동주택을 중심으로", 설비공학 논문집, 20(11), pp.746~751 (2008), 대한설비공학회