한국 산업용 건물지붕 적용 PV에 의한 발전량 및 CO2 분석연구
A Study on Electric Capacity and CO2 by the Roof Top PV System of the Industrial Building in Korea
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
The purpose of this study is to provide foundational data for expansion of solar generation in building application, a clean energy, by introducing applicability of solar power generation system on roofs of industrial buildings and computing expected amounts of power and carbon dioxides reduction. As methodologies of this study, after reviewing 120,000 domestic factories to verify the BIPV feasibility for industrial buildings through theoretical considerations of solar generation system, we calculated BIPV application methods and subsequent expected power generation quantity and carbon dioxide reductions through roof type analysis. we analyzed four cases of expected power generation amounts of solar batteries according to application methods, and when considering that the main type of roofs are slant roofs according to the investigation result about roof forms of domestic industrial complexes, we believe that the module angle of a slant roof around 17°(case 3) is most suitable for the application. Finally, we came up with 517,944 [TOE] as the corresponding petroleum tonnage based on this computed expected power generation amount and the amount of 1,214,836 [tCO2] carbon dioxide reductions by calculating them by energy sources.
Abstract
The purpose of this study is to provide foundational data for expansion of solar generation in building application, a clean energy, by introducing applicability of solar power generation system on roofs of industrial buildings and computing expected amounts of power and carbon dioxides reduction. As methodologies of this study, after reviewing 120,000 domestic factories to verify the BIPV feasibility for industrial buildings through theoretical considerations of solar generation system, we calculated BIPV application methods and subsequent expected power generation quantity and carbon dioxide reductions through roof type analysis. we analyzed four cases of expected power generation amounts of solar batteries according to application methods, and when considering that the main type of roofs are slant roofs according to the investigation result about roof forms of domestic industrial complexes, we believe that the module angle of a slant roof around 17°(case 3) is most suitable for the application. Finally, we came up with 517,944 [TOE] as the corresponding petroleum tonnage based on this computed expected power generation amount and the amount of 1,214,836 [tCO2] carbon dioxide reductions by calculating them by energy sources.
참고문헌 (5)
- 이응직, "지붕일체형 PV모듈의 건축특성 및 적용사례 분석연구", 한국생태환경건축학회논문집, 6(3), pp.49~56 (2006)
- Eung-Jik Lee, "Untersuchung der Anwendu ngsmoglichkeiten von Photovoltaik an Gebauden in Sudkorea", 1999.5, Lehrstuhl fur Klimagere chte Architektur Universitat Dortmund, ~ (1999)
- 이재형, "태양전지 원론", 홍릉과학출판사
- 태양열에너지 기술개발 현황 및 전망, , 설비기술, 82~92 (2006)
- Planning and Installing Photovoltaic Systems, "A guide for installers, architects and engineers" (2005), JAMES & JAMES