In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER’s TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

Abstract

In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER’s TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

참고문헌 (19)

  1. Perez, R., "Modeling Daylight Availability and Irradiance Components from Direct and Global Irradiance", Solar Energy, 44(5), pp.271~289 (1990)
  2. Seo, D., "Hourly Solar Radiation Model Suitable for Worldwide Typical Weather File Generation", Journal of Solar Energy Engineering, 113, pp.1~8 (2011)
  3. 서동현, "대한민국 표준기상 데이터 개발을 위한 솔라모델 성능 비교", 대한건축학회연합논문집, 12(1), pp.147~154 (2010), 대한건축학회지회연합회
  4. MOLIT, "Window Design Guide for Building Energy Efficiency", Ministry of Land, Infrastructure, and Transpotation, ~ (2012)
  5. 최안섭, "광센서 조광제어시스템의 효율적 적용을 위한 조광제어구역 결정에 관한 연구", 대한건축학회논문집 계획계, 21(6), pp.157~164 (2005), 대한건축학회
  6. Christoph, R., "Tutorial on the Use of Daysim Simulation for Sustainable Design", NRCC, ~ (2006)
  7. "CIBSE BS 8206-2:2008, Lighting for Buildings. Code of Practice for Daylighting", ~ (2008)
  8. 고동환, "기상데이터 기반 동적 자연채광 시뮬레이션을 이용한 유용조도 분석에 관한 연구", 대한건축학회논문집 계획계, 26(06), pp.321~331 (2010), 대한건축학회
  9. 오명환, "BIM 도구를 활용한 초기설계단계의 기상데이터 기반 자연채광성능 평가방법에 관한 연구", 대한건축학회논문집 계획계, 27(06), pp.267~274 (2011), 대한건축학회
  10. 김한용, "그린빌딩 인증기준에 따른 자연채광성능 평가와 설계요소에 따른 주광 예측에 관한 연구", 대한건축학회논문집 계획계, 29(07), pp.239~246 (2013), 대한건축학회
  11. Christoph, R., "Experimental Validation Of 3D Max Design 2009 and Daysim 3.0", Eleventh International IBPSA Conference Glasgow (2009)
  12. Ihm, P., "Estimation of Lighting Energy Savings from Daylighting", Build Environ, 44, pp.509~514 (2009)
  13. Li, D. H. W., "Study of Daylight Data and Lighting Energy Savings for Atrium Corridors with Lighting Dimming Controls", Energy Build, 72, pp.457~464 (2014)
  14. Yun, G. Y., "Effects of Occupancy and Lighting Use Patterns on Lighting Energy Consumption", Energy Build, 46, pp.152~ (2012)
  15. Chen, Y., "Experimental and Simulation Study on the Performance of Daylighting in an Industrial Building and Its Energy Saving Potential", Energy Build, 73, pp.184~191 (2014)
  16. Krarti, M., "A Simplified Method to Estimate Energy Savings of Artificial Lighting Use from Daylighting", Build Environ, 40, pp.747~754 (2005)
  17. Roisin, B., "Lighting Energy Savings in Offices using Different Control Systems and Their Real Consumption", Energy Build, 40, pp.514~523 (2008)
  18. Muneer, T., "Solar Radiation and Daylight Models" (2004), Butterworth-Heinemann
  19. Cucumo, M., "Correlations of Global and Diffuse Solar Luminous Efficacy for All Sky Conditions and Comparisons with Experimental Data of Five Localities", Renewable Energy, 33(9), pp.2036~2047 (2008)