가압식 바닥공조 시스템과 야간 외기냉방의 병용에 따른 에너지저감 성능에 관한 연구
A Study on Energy Saving Performance by Night Purge Cooling with Pressurized Under Floor Air Distribution System
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20°C. However, when To was 22°C, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20°C was reduced by 27% compared to that of operating NPC continuously for 8 hours.
Abstract
It has been reported about the energy saving performance of UFAD(under floor air distribution) system and NPC(night purge cooling) system respectively which are applied for commercial buildings. However, when two systems are used at the same time, the effect of heat transfer from floor plenum to slab may vary depending on the operating conditions of NPC. In this study, cooling energy demands were analyzed for building models with UFAD and NPC by using TRNSYS 17 program. UFAD was applied as a cooling system of the base building model, and the cooling energy demands were compared for 64 cases in which the operating time, supply airflow rate, and outdoor air temperature(To) of NPC. As a result, it was confirmed that the cooling energy demands were reduced to 30 ~ 80% level compared to UFAD alone, and in particular, the energy demand was reduced in proportion to the supply airflow rate or the operating time while To was 16 ~ 20°C. However, when To was 22°C, the increase in the supply airflow rate or the operating time results in a disadvantage in terms of cooling energy demands. In addition, the cooling energy demands for UFAD+NPC model were analyzed by applying weather data from three regions with different average outdoor air temperatures. As a result, the cooling energy demand of operating NPC only when To was below 20°C was reduced by 27% compared to that of operating NPC continuously for 8 hours.
참고문헌 (7)
- Ali Alajmi, "Saving energy by using underfloor-air-distribution(UFAD)system in commercial buildings", Energy Conversion and Management, 51, pp.1637~1642 (2010)
- Yu, K. H., "Influence of lighting loads upon thermal comfort under CBAD and UFAD systems", Energies, 8, pp.6079~6097 (2015)
- Bauman, "Underfloor Air Distribution (UFAD) Design Guide", ASHRAE, ~ (2003)
- Miura, K., "Evaluation of thermal load reduction and effect to indoor environment by hybrid ventilation system", Journal of environmental engineering(Transaction of AIJ), 76(660), pp.159~168 (2011)
- 정재훈, "실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토", 설비공학 논문집, 22(10), pp.719~726 (2010), 대한설비공학회
- 김수연, "전열교환형 환기시스템을 이용한 학교건물의 나이트 퍼지 적용 효과 분석", 설비공학 논문집, 28(11), pp.421~427 (2016), 대한설비공학회[DOI]
- 윤성훈, "실내 부하조건에 따른 바닥공조 시스템의 에너지 성능 평가", 설비공학 논문집, 25(1), pp.14~19 (2013), 대한설비공학회[DOI]