축소모형을 이용한 방음터널의 자연채광성능평가에 관한 연구
A Study on the Evaluation of the Daylighting Performance in the Sound Barrier Tunnel
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Abstract
This study aims to evaluate the natural lighting performance in the sound barrier tunnel. Therefore, to evaluate the daylighting performance, the combinations of 3 tunnel roof types which are flat-roof-type(type A), slope-roof-type(type B), arch-roof-type(type C) and 3 window types which are side-window-type(type 1), one-window-roof type(type 2), two-window-roof type(type 3) are evaluated by experimenting small scaled models. In this 9 cases of experiment, illuminance levels of each case are analyzed and evaluated. The conclusion of this study is that slope-roof-type(B) and arch-roof-type(C) is preferable to flat-roof-type(A) and one-window-roof-type(B) and two-window-roof-type(C) is preferable to side-window-type(A) for daylighting in the sound barrier tunnel.
참고문헌 (6)
- "건축환경계획" (2002)
- "도로터널 조명시설 설계기준" (1995)
- "도로교통협회 도로설계기준" (2000)
- "^도로터널 조명시설의 설계기준" (1996)
- "한국산업규격 터널 조명 기준" (1992)
- "조도기준(KS A 3011)," (1998)