주상복합 건축물의 기초 슬래브에 설치된 수평형 지열교환기의 계절별 성능평가
A Study on the Seasonal Performances Evaluation of the Horizontal-type Geothermal Heat Exchanger Installed in the Foundation Slabs of Complex Building
1
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Abstract
This study evaluates the seasonal performances of the horizontal-type geothermal heat exchanger(HGHEX) installed into the foundation slabs of the complex building located at Seoul. The geothermal system is consisted with totally 31,860m long HGHEX, 16 GSHPs (Ground-source Heat Pump) and 8 circulation pumps. This system supplies cooling and heating to the lobby(F1) and the common spaces(BF1). The average heat exchange temperature differences are 2.7℃ and 2.5℃ in the summer, 1.5℃ and 0.5℃ in the winter for the F1 and BF1 respectively. From these results, approximately 400Gcal and 180Gcal of geothermal energy are assumed to have been used during the summer and winter seasons respectively. As a conclusion, the geothermal system is reviewed as a effective utility for heating and cooling at the point of seasonal performances.
참고문헌 (12)
- "대체에너지개발 및 이용보급 촉진법 제11조제2항(2002.3)" (2004), 산업자원부
- "지열펌프 냉난방 시스템" (2005), 한림원
- "지열 이용 열펌프 시스템의 성능평가기법 및 기술기준(안) 구축 보고서" (2005)
- "지열냉난방시스템 적용을 위한 지반의 열전도 특성에 관한 연구" (2005)
- "측정 자료가 없는 지역의 지중온도 예측방법에 관한 연구" (2003)
- "지열교환기 의 열교환 성능에 관한 연구" (2003)
- "1차원 모델 에 의한 지중열교환기의 열거동 해석" (2005)
- "GSHP용 수평형 지중열교환기의 열전달 성능에 관한 실험적 연구" (2005)
- "Experimental thermal performance evaluation of a horizontal ground-source heat pump system", 24, pp.2219~2232 (2004)
- "지중열원 열펌프시스템의 성능해석" (2005)
- "지열 이용히트펌프 시스템의 열성능 해석" (2006)
- "주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가" (2006)