This study was conducted to forecast inner water temperature strata change by extracting deep water from a dam. For the methodology, the scope wherein the balance between the volume of low-temperature water intake through the virtual water intake opening as installed within the stored water area and the volume of water intake from the surrounding area is not destroyed was calculated through the CFD simulation technique using the computational fluid dynamics(CFD) interpretation method. This study suggested a supplementary method (diffuser) to avoid destroying the water temperature strata, and the effect was reviewed. In case of intake of the same volume, when the velocity of flow of water intake is reduced by increasing the pipe diameter, the destruction of water temperature strata can be minimized. When the area (height) where the intake of water is possible is low, a diffuser for interrupting the vertical direction inflow should be installed to secure favorable water intake conditions in case of water intake on the upper part. This study showed that there was no problem if the intake-enabled, low-temperature area was secured approximately 10m from the bottom when the scope that does not destroy the water temperature strata in case of water intake was forecast using the regression formula.

Abstract

This study was conducted to forecast inner water temperature strata change by extracting deep water from a dam. For the methodology, the scope wherein the balance between the volume of low-temperature water intake through the virtual water intake opening as installed within the stored water area and the volume of water intake from the surrounding area is not destroyed was calculated through the CFD simulation technique using the computational fluid dynamics(CFD) interpretation method. This study suggested a supplementary method (diffuser) to avoid destroying the water temperature strata, and the effect was reviewed. In case of intake of the same volume, when the velocity of flow of water intake is reduced by increasing the pipe diameter, the destruction of water temperature strata can be minimized. When the area (height) where the intake of water is possible is low, a diffuser for interrupting the vertical direction inflow should be installed to secure favorable water intake conditions in case of water intake on the upper part. This study showed that there was no problem if the intake-enabled, low-temperature area was secured approximately 10m from the bottom when the scope that does not destroy the water temperature strata in case of water intake was forecast using the regression formula.

참고문헌 (5)

  1. 김지혜, "기후 온난화의 영향에 의한 건물의 냉·난방에너지 수요량 예측", 한국태양에너지학회 논문집, 26(3), pp.119~126 (2006), 한국태양에너지학회
  2. 심경종, "수온층을 고려한 저층수 취수 기술에 관현 연구", 대한설비공학회 하계학술 발표대회 논문집, pp.1285~1290 (2008)
  3. 김기철, "건물의 냉방을 위한 해수열 취득에 관한 실험적 연구", 한국마린엔지니어링학회지, 29(8), pp.883~890 (2005), 한국마린엔지니어링학회
  4. Fox, R. W., "Introduction to Fluid Mechanics, 5th edition" (1998), John Wiley & Sons, Inc.
  5. John J. Cruz, "Sea water air conditioning for Tumon Bay, Guam, Guam power authority", ~ (2005)

관련 논문AI추천

이 간행물의 다른 논문 (9건)