사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가
Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer
0
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum 3.2℃ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.
Abstract
The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum 3.2℃ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.
참고문헌 (6)
- 김수봉, "친환경적 도시계획 : 도시열섬연구 초판", pp.165~ (2006), 문운당
- 윤성환, "3차원 전표면온도 수치시뮬레이션에 의한 판상형 및 탑상형 아파트의 여름철 옥외 열환경 평가", 대한건축학회논문집 계획계, 24(10), pp.259~266 (2008), 대한건축학회
- 유호천, "에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구", 한국태양에너지학회 논문집, 25(4), pp.53~60 (2005), 한국태양에너지학회
- 정선영, "아파트 주동형상에 따른 옥외 열쾌적성 및 열섬잠재성 예측평가", 대한건축학회 학술발표대회 논문집, 28(1)통권 : 52, pp.547~550 (2008)
- Shinji Yamamura, "築外部空間デザインの設計支援を目的とした熱放射環境の予測手法の開発", Archit. Plann. Environ. Eng., AIJ, pp.85~92 (2002)
- Takashi Asawa, "Thermal design tool for outdoor spaces based on heat balance simulation using 3D-CAD system", Building and Environment, 43, pp.2112~2123 (2008)
