재해임시주거 냉난방을 위하여 기존 에어컨을 열펌프로 전환하는 변환기 개발

Development of a Conversion Unit converting the existing air conditioner to Heat Pump System for the Emergency Shelter

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from 27℃ to 39℃ by the air conditioner converted to a heat pump system with the ambient temperature variation of -10℃∼10℃, and cooled from 20℃to 15℃ by the converted system with the ambient temperature variation of 20℃∼ 35℃. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of -10℃∼10℃, respectively, whereas the cooling COP decreased from 3.1 to 2.1 with the increase of the ambient temperature from 20℃ to 35℃.

Abstract

Korea and some other countries located in the northern hemisphere employ the air conditioner for the space cooling in the hot summer season and also some kinds of heaters for the space heating in the cold winter season. Especially in Korea, a great number of air conditioners of about 12,700,000 sets have been used these days. However, they are used for a short operation period of only 58 days a year, which results in the material and economic losses. To solve this problem and employ this system for the emergency shelter, a new conversion unit which could convert the existing air conditioner to a heat pump system for simultaneous heating and cooling was developed in this study, and the thermal performance was tested. The results indicated that the indoor air could be heated from 27℃ to 39℃ by the air conditioner converted to a heat pump system with the ambient temperature variation of -10℃∼10℃, and cooled from 20℃to 15℃ by the converted system with the ambient temperature variation of 20℃∼ 35℃. And also the heating COP increased from 3.3 to 5.3 in case of the heat exchange of the super cooling(HESC) circuit and from 3.0 to 4.0 in case of the By-pass with the ambient temperature variation of -10℃∼10℃, respectively, whereas the cooling COP decreased from 3.1 to 2.1 with the increase of the ambient temperature from 20℃ to 35℃.

참고문헌 (6)

  1. 한윤호, "열환경의 쾌적범위에 관한연구", 대한건축학회논문집, 4(4)통권 : 18, pp.157~166 (1986)
  2. 유환규, "가정용 냉방기의 대체냉매 성능분석을 위한 전산 해석 연구", 한국태양에너지학회지, 15(3) (1995)
  3. FuadKent,E, "PerformanceEvolutionof aCompactAir-to-airHeatpump", Energy Convers, 38(4) (1997)
  4. Marchal,D.A, "Simulation modelof refrigerantingandAir-conditioningEquipment basedonexperimentaldata,ASHRAE3532", ~
  5. OlympiaZ, "Effectofclimatic condition on thedesign optimization of heatpumpsystemsforspaceheatingand cooling", EnergyConvers, 39(7) (1998)
  6. BlundellC.J, "OptimizingHeatExchangers forAir-to-AirspaceHeatingHeatpumps intheU.K", Int.J,EnergyRes, 1 (1997)

관련 논문AI추천

이 간행물의 다른 논문 (19건)