본문 바로가기
KERD
논문KCI 등재

환기 유무에 따른 CIGS BIPV 커튼월 유닛의 성능 비교 분석

Comparison of Performance Analysis of the Ventilated and Nonventilated CIGS BIPV Units

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류기타공학

초록

CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was 6.8°C lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

Abstract

CIGS thin film solar cells are technically suitable for BIPV applications than regularly used crystalline silicon solar cells. Particularly, CIGS PV has lower temperature coefficient than crystalline silicon PV, thus decrease in power generation is lowered in CIGS PV. Moreover, CIGS PV can decrease shading loss when applied to the BIPV system, and the total annual power generation is higher than crystalline silicon. However, there are few studies on the installation factors affecting the performance of BIPV system with CIGS module. In this study, BIPV curtain wall unit with CIGS PV module was designed. To prevent increase of temperature of CIGS PV module by solar radiation, ventilation was considered at the backside of the unit. The thermal specification and electrical performance of CIGS PV of the ventilated unit was analyzed experimentally. Non-ventilated unit was also investigated and compared with ventilated unit. The results showed that the average CIGS temperature of the ventilated curtain wall unit was 6.8°C lower than non-ventilated type and the efficiency and power generation performance of ventilated CIGS PV on average was, respectively, about 6% and 5.8% higher than the non-ventilated type.

참고문헌 (15)

  1. Kim, J. H., "The Performance Evaluation of the BIPV System Considering Photovoltaic Module Temperature", Journal of the Korean Solar Energy Society, 5, pp.53~58 (2004)
  2. 김지성, "BIPV 적용을 위한 CIGS 박막 태양전지의 특성 분석연구", 석사, 건축공학과 건축환경전공, pp.2013
  3. Beck, M. E., "Advancements in Flexible CIGS Module Manufacturing", Conference Record of the Thirty-First IEEE, pp.211~214 (2005)
  4. Wiedeman, S., "CIGS Module Development on Flexible Substrates", Conference Record of the Twenty-Ninth IEEE, pp.575~578 (2002)
  5. Malmstrom, J., "A Study of the Influence of the Ga Content on the Long-term Stability of Cu(In,Ga)Se2 thin film solar cells", Thin Solid Films, (421), pp.436~442 (2003)
  6. Kang, J. G., "The Characteristics on CIGS Thin Film PV Module for Curtain Wall Applications", 4, pp.257~261 (2013)
  7. Lee, J. H., "CIGS Compound Thin Film Solar Cell Technology Development and Industry Trend", Journal of the Korean Institute of Electrical Engineers, 61(11), pp.23~36 (2012)
  8. Yoon, J. H., "Industry Trends and Future Technologies of CIGS Thin Film Solar Cell", The Magazine of the Institute of Electronics and information Engineers, 35(6), pp.50~58 (2008)
  9. 최승훈, "CIGSe2 박막태양전지용 Mo 하부전극의 물리·전기적 특성 연구", 한국진공학회지, 21(3), pp.142~150 (2012), 한국진공학회
  10. Lee, J. H., "Development Trend of Cu(In, Ga)Se2 Thin Film Solar Cell Technology", Journal of the Korean Solar Energy Society, 10(4), pp.12~26 (2011)
  11. Virtuani, A., "Overview of temperature coefficients of different thin film photovoltaic technologies", 25th European Photovoltaic Solar Energy Conference and Exhibition, 2010, 6~10
  12. Feist, R., "Methodology for Delivering Reliable CIGS based Building Integrated Photovoltaic(BIPV) Products", Reliability Physics Symposium(IRPS), 2012 IEEE International, pp.4A-1~ (2012)
  13. 이상길, "모델링 기법을 이용한 스팬드럴 적용 BIPV의 열 및 전기적 특성에 관한 연구", 석사, 에너지시스템공학과, pp.2013
  14. Kim, H. R., "Electrical Characteristics of Semi-transparent BIPV Module with Backside Glass", Jonural of the Korean Institute of Electrical Engineers, 7, pp.1300~1301 (2011)
  15. Park, K. E., "Analysis of Thermal and Electrical Performance of semi-transparent photovoltaic(PV) module", Energy, 35(6), pp.2681~2687 (2010)

관련 논문AI추천