초록

This study proposes an appropriate level of insulation standards by region through annual heating energy requirements according to regional climate. The reference buildings out of non-residential buildings approved by the energy saving design standard for buildings were derived in the previous study, in which the annual heating energy requirements for each building were as follows when the insulation standard for building members in four regions (Pyeongchang, Seoul, Gwang-ju, and Jeju) suggested by the energy saving design standard for buildings: 29.8 kWh/m 2 in Pyeongchang,17.5 kWh/m 2 in Seoul,14.4 kWh/m 2 in Gwangju, and 16.7 kWh/m 2 in Jeju. To satisfy the passive level of insulation standards for these buildings, in case that roof/floor of buildings in Pyeongchang and Seoul was 0.2 W/m 2 K, the minimum window thermal transmittance should satisfy 0.9 W/m 2 K and the minimum wall thermal transmittance should satisfy 0.1 W/m 2 K in the case of Pyeongchang. On the other hand, the minimum window thermal transmittance should satisfy 1.5 W/m 2 K and the minimum wall thermal transmittance should satisfy 0.14 W/m 2 K in the case of Seoul. For Jeju regions, the minimum wall thermal transmittance should satisfy 0.34 W/m 2 K to meet the passive level of buildings. Based on the above results, the thermal transmittance of each member by region should take the outdoor climate condition of the region into consideration to satisfy the passive level of buildings.

Abstract

This study proposes an appropriate level of insulation standards by region through annual heating energy requirements according to regional climate. The reference buildings out of non-residential buildings approved by the energy saving design standard for buildings were derived in the previous study, in which the annual heating energy requirements for each building were as follows when the insulation standard for building members in four regions (Pyeongchang, Seoul, Gwang-ju, and Jeju) suggested by the energy saving design standard for buildings: 29.8 kWh/m 2 in Pyeongchang,17.5 kWh/m 2 in Seoul,14.4 kWh/m 2 in Gwangju, and 16.7 kWh/m 2 in Jeju. To satisfy the passive level of insulation standards for these buildings, in case that roof/floor of buildings in Pyeongchang and Seoul was 0.2 W/m 2 K, the minimum window thermal transmittance should satisfy 0.9 W/m 2 K and the minimum wall thermal transmittance should satisfy 0.1 W/m 2 K in the case of Pyeongchang. On the other hand, the minimum window thermal transmittance should satisfy 1.5 W/m 2 K and the minimum wall thermal transmittance should satisfy 0.14 W/m 2 K in the case of Seoul. For Jeju regions, the minimum wall thermal transmittance should satisfy 0.34 W/m 2 K to meet the passive level of buildings. Based on the above results, the thermal transmittance of each member by region should take the outdoor climate condition of the region into consideration to satisfy the passive level of buildings.

참고문헌 (12)

  1. "Energy Statistical Yearbook in Korea Energy Agency", ~ (2015)
  2. "Energy Balances of OECD countries", IEA, ~ (2015)
  3. 윤용상, "국내 지역기후와 연간 난방에너지요구량의 상관관계 분석 연구 - 패시브하우스 성능 건축물을 중심으로 -", 대한건축학회논문집 계획계, 30(1), pp.209~216 (2014), 대한건축학회
  4. 이명주, "건축물에너지절약요소기술 적용에 따른 단독주택 에너지 요구량 절감률 변화에 관한 연구", 대한건축학회논문집 계획계, 28(05), pp.275~282 (2012), 대한건축학회
  5. Koh, G. H., "Study on Technical Analysis of Regional Climate Sustainable Building-Focused on passive techniques", 35(1), pp.327~328 (2015)
  6. Wolfgang. Feist, "Re-inventing air heating: Convenient and comfortable within the frame of the Passive house concept", Energy and Buildings, 37, pp.1186~1203 (2005)
  7. "Lernzielkatalog 'Zertifizierter PassivhausPlaner'", Wolfgang Feist, PASSIV HAUS INSTITUT, ~
  8. "EN ISO 13790:2008 thermal performance of buildings - calculation of energy use for space heating and cooling", ISO, ~ (2008)
  9. Yeweon Kim, "Study on Extension of Standard Meteorological Data for Cities in South Korea Using ISO 15927-4, Vol. 8, No. 11", ~
  10. 정해권, "건축물에너지효율등급 인증 받은 업무용 건축물과 비인증 업무용 건축물의 에너지성능지표 득점 비교 분석", 대한건축학회논문집 계획계, 31(3), pp.163~170 (2015), 대한건축학회[DOI]
  11. "Regulation on Operation of Building Energy Efficiency Grade Certification System", Korea Energy Agency, ~
  12. "Korea Meteorogical Administration"[URL]