초록

When Photovoltaic inverter is connected to grid and used as PVPCS (Photovoltaic Power Conditioning System), 120 Hz AC ripple occurs at the dc-link capacitor voltage. This AC ripple reduces the efficiency of PVPCS and shortens the lifetime of the capacitor. In this paper, we design a notch filter to remove AC ripple. As a result, the AC voltage ripple was removed from the dc link and the THD of the PVPCS output current with the notch filter was lowered. This notch filter is determined by the damping coefficient, the bandwidth coefficient, and the switching frequency. Among these, the switching frequency determines the switching loss and the size of the LC filter, and the PVPCS with the high switching frequency has a greater efficiency loss due to the switching loss than the efficiency improvement by the notch filter. Therefore, it is important to set the optimum switching frequency in the PVPCS with the notch filter applied. In this paper, THD and switching loss of PVPCS output current with notch filter are calculated through simulation, and cost function to calculate optimum switching frequency through data is proposed.

Abstract

When Photovoltaic inverter is connected to grid and used as PVPCS (Photovoltaic Power Conditioning System), 120 Hz AC ripple occurs at the dc-link capacitor voltage. This AC ripple reduces the efficiency of PVPCS and shortens the lifetime of the capacitor. In this paper, we design a notch filter to remove AC ripple. As a result, the AC voltage ripple was removed from the dc link and the THD of the PVPCS output current with the notch filter was lowered. This notch filter is determined by the damping coefficient, the bandwidth coefficient, and the switching frequency. Among these, the switching frequency determines the switching loss and the size of the LC filter, and the PVPCS with the high switching frequency has a greater efficiency loss due to the switching loss than the efficiency improvement by the notch filter. Therefore, it is important to set the optimum switching frequency in the PVPCS with the notch filter applied. In this paper, THD and switching loss of PVPCS output current with notch filter are calculated through simulation, and cost function to calculate optimum switching frequency through data is proposed.

참고문헌 (6)

  1. Kim, S. M., "The Feed-forward Controller and Filter design of Single-Phase Power Conditioning System for Mitigation Current Ripple", KSES Spring Annual Conference (2012)
  2. 김승민, "연료전지용 PCS의 출력 전류 리플 개선을 위한 노치 필터 설계", 한국태양에너지학회 논문집, 32(6), pp.106~112 (2012), 한국태양에너지학회
  3. Kotato, H., "Design of Digital Notch Filters", IEEE Transactions on Communications, COM-22(7) (1974)
  4. 양승대, "3상 양방향 인버터의 계통전압 불평형 및 왜곡에 의한 계통전류 보상", 한국태양에너지학회 논문집, 32(3), pp.228~234 (2012), 한국태양에너지학회[DOI]
  5. You, J. M., "Thermal Modeling and Simulation Using PSIM", KIPE MAGAZINE, 22(3), pp.34~38 (2017)
  6. "TRINNO TECHNOLOGY Datasheet TGN40N60F2DL 2017", ~ (2017)