본문 바로가기
KERD
논문KCI 등재

제로에너지건물 사례를 통한 부하매칭율 및 건물과 계통간의 송·수전량 변동성 분석

Analysis of Load Matching and Grid Interaction of a Zero Energy Building

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

Zero energy buildings apply energy efficiency measures and renewable energy systems to maintain a zero energy consumption balance over a specific time. Renewable energy systems installed in zero energy buildings produce energy to cover their energy demand, and the surplus energy can be transmitted to the grid. Conversely, the building can receive power from the grid when the energy consumption is greater than the energy production. However, the greater fluctuation of transmitted and received power in the transfer process results in lower grid stability. Therefore, for zero energy buildings, it is necessary to evaluate the load matching rate and power transmission between the building and the grid. However, in the case of zero-energy building certification in Korea, it is impossible to evaluate the load matching rate because it only considers the building's annual energy consumption and production volume. This study investigated the energy balance of a zero energy building-certified case in terms of load matching and grid interaction evaluation indicators. Based on the results, the Load Cover Factors (LCF) analyzed at intervals of 10 minutes, 1 day, and one month were 0.421, 0.929, and 0.996, and, correspondingly, the Supply Cover Factors (SCF) were 0.228, 0.544, and 0.536 under the same analysis conditions. In addition, the variabilities of the amount of transmitted and received power were confirmed to be 0.203, 0.286, and 0.305, respectively.

Abstract

Zero energy buildings apply energy efficiency measures and renewable energy systems to maintain a zero energy consumption balance over a specific time. Renewable energy systems installed in zero energy buildings produce energy to cover their energy demand, and the surplus energy can be transmitted to the grid. Conversely, the building can receive power from the grid when the energy consumption is greater than the energy production. However, the greater fluctuation of transmitted and received power in the transfer process results in lower grid stability. Therefore, for zero energy buildings, it is necessary to evaluate the load matching rate and power transmission between the building and the grid. However, in the case of zero-energy building certification in Korea, it is impossible to evaluate the load matching rate because it only considers the building's annual energy consumption and production volume. This study investigated the energy balance of a zero energy building-certified case in terms of load matching and grid interaction evaluation indicators. Based on the results, the Load Cover Factors (LCF) analyzed at intervals of 10 minutes, 1 day, and one month were 0.421, 0.929, and 0.996, and, correspondingly, the Supply Cover Factors (SCF) were 0.228, 0.544, and 0.536 under the same analysis conditions. In addition, the variabilities of the amount of transmitted and received power were confirmed to be 0.203, 0.286, and 0.305, respectively.

참고문헌 (9)

  1. "2030 Nationally Determined Contributions(NDC) Upward Plan" (2021)[URL]
  2. Ahn, J. B., "Distributed Generation and Grid Connection Technology", Journal of Electrical World Monthly Magazine, 347, pp.12~20 (2005)
  3. Salom, J., "Understanding Net Zero Energy Buildings: Evaluation of Load Matching and Grid Interaction Indicators", 12th Conference of International Building Performance Simulation Association (2011)
  4. Salom, J., "Analysis of Load Match and Grid Interaction Indicators in Net Zero Energy Buildings with Simulated and Monitored Data", Applied Energy, 136, pp.119~131 (2014)
  5. Voss, K., "Load Matching and Grid Interaction of Net Zero Energy Buildings", EuroSun 2010, Graz (2010)
  6. 김법전, "넷 제로에너지주택의 부하매칭에 관한 연구", 한국태양에너지학회 논문집, 38(4), pp.55~66 (2018), 한국태양에너지학회[DOI]
  7. 나호준, "CR리츠를 활용한 미분양 주택 유동화 지원정책 분석- 시스템다이내믹스를 이용하여 -", 한국건설관리학회 논문집, 14(5), pp.12~25 (2013), 한국건설관리학회[DOI]
  8. "Current status of technology applied to Seoul Energy Dream Center" (2017)[URL]
  9. 이제훈, "일 단위 전력소비 고변동성 그룹에 대한 군집화 및 결정요인 분석", 응용경제, 22(1), pp.95~127 (2020), 한국응용경제학회