In this study, the application of a medical compression sleeve of Moisture Responded Transformable(MRT) fibers to the treatment of lymphedema after surgery in breast cancer patients was investigated. MRT fibers were manufactured with PET and Nylon6 bi-component cross-section yarns, and compression sleeves of sleeves 1, 2, 3, and 4 were knitted in order of size, and then the physical properties and clinical tests were evaluated. As a result, the pressure of compression sleeve in wrinkle was the lowest in sleeve 1 with 3.81 kPa, and the highest in sleeve 4 with 5.22 kPa. Elastic recovery rate is that all parts except the top of the sleeve 1 exhibited 100%. The air permeability was good at 12.1 ~ 16.1 cm3/cm2/sec, and peeling was also comparatively excellent as grade 3. In addition, the weight of the compression sleeves 1, 2, and 3 decreased as 18.3 ~ 23.0 g/m2 depend on size, while the compared sample was heavier with 17.39 ~ 32.61 g/m2. In lymphoscintigraphy test, it was confirmed that the function of remaining lymph node was good in all patients. Although there were no differences between samples in skin irritation and tightness in wearing comfort, the manufactured sleeves showed better fit, lightness, fashion and breathability than the comparable sleeves.
Abstract
In this study, the application of a medical compression sleeve of Moisture Responded Transformable(MRT) fibers to the treatment of lymphedema after surgery in breast cancer patients was investigated. MRT fibers were manufactured with PET and Nylon6 bi-component cross-section yarns, and compression sleeves of sleeves 1, 2, 3, and 4 were knitted in order of size, and then the physical properties and clinical tests were evaluated. As a result, the pressure of compression sleeve in wrinkle was the lowest in sleeve 1 with 3.81 kPa, and the highest in sleeve 4 with 5.22 kPa. Elastic recovery rate is that all parts except the top of the sleeve 1 exhibited 100%. The air permeability was good at 12.1 ~ 16.1 cm3/cm2/sec, and peeling was also comparatively excellent as grade 3. In addition, the weight of the compression sleeves 1, 2, and 3 decreased as 18.3 ~ 23.0 g/m2 depend on size, while the compared sample was heavier with 17.39 ~ 32.61 g/m2. In lymphoscintigraphy test, it was confirmed that the function of remaining lymph node was good in all patients. Although there were no differences between samples in skin irritation and tightness in wearing comfort, the manufactured sleeves showed better fit, lightness, fashion and breathability than the comparable sleeves.
참고문헌 (12)
- H. A. Kim, "Moisture Responded Transformable Property of Intelligent Coolness Knitted Fabrics for Sportswear Clothings", Autex Research Journal, 17(3), pp.238~ (2017)
- S. Chen, "An Experimental Study of the Compression Properties of Polyurethane-Based Warp-Knitted Spacer Fabric Composites", Autex Research Journal, 17(3), pp.199~ (2017)
- Q. S. Lu, "Optimization on the Thermal and Tensile Influencing Factors of Polyurethane Based Polyester Fabric Composites", Composites Part A, 41, pp.997~ (2010)
- S. H. Kim, "Conservative Treatment of Lymphedema", KAUTPT, 6(1), pp.62~ (1999)
- 임창훈, "상지운동과 붕대법이 상지림프부종 환자의 부종과 관절가동범위에 미치는 영향", 대한물리의학회지, 6(1), pp.31~38 (2011), 대한물리의학회
- K. Ochalek, "Preventing Early Postoperative Arm Swelling and Lymphedema Manifestation by Compression Sleeves After Axillary Lymph Node Interventions in Breast Cancer Patients : A Randomized Controlled Trial", Journal of Pain Symptom Management, 54, pp.346~ (2017)
- B. Rogina, "Physicochemical Characterization of the Multiuse Medical Textiles in Surgery and as Packaging Material in Medical Sterilization", Autex Research Journal, 17(3), pp.206~ (2017)
- Q. S. Lu, "Optimization on the Thermal and Tensile Influencing Factors of Polyurethane-based Polyester Fabric Composites", Composites Part A Applied Science and Manufacturing, 41(8), pp.997~ (2010)
- 김성중, "임파부종 환자의 보존적 치료법", 한국전문물리치료학회지, 6(1), pp.62~73 (1999), 한국전문물리치료학회
- H. G. Kim, "The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in Breast Cancer", Journal of Radiological Science and Technology, 29(2), pp.75~ (2006)
- H. S. Lee, "Predicting Nonsentinel Lymph Node Metastasis Using Lymphoscintigraphy in Patients with Breast Cancer", Journal of Nuclear Medicine, 53(11), pp.1693~ (2012)