초록

This paper describes an experimental investigation of the effect of cooling flow rate on gas foil thrust bearing (GFTB) performance. In a newly developed GFTB test rig, a non-contact type pneumatic cylinder provides static loads to the test GFTB and a high-speed motor rotates a thrust runner up to the maximum speed of 80 krpm. Force sensor, torque arm connected to another force sensor, and thermocouples measures the applied static load, drag torque, and bearing temperature, respectively, for cooling flow rates of 0, 25, and 50 LPM at static loads of 50, 100, and 150 N. The test GFTB with the outer radius of 31.5 mm has six top foils supported on bump foil structures. During the series of tests, the transient responses of the bearing drag torque and bearing temperature are recorded until the bearing temperature converges with time for each cooling flow rate and static load. The test data show that the converged temperature decreases with increasing cooling flow rate and increases with increasing static load. The drag torque and friction coefficient decrease with increasing cooling flow rate, which may be attributed to the decrease in viscosity and lubricant (air) temperature. These test results suggest that an increase in cooling flow rate improves GFTB performance.

Abstract

This paper describes an experimental investigation of the effect of cooling flow rate on gas foil thrust bearing (GFTB) performance. In a newly developed GFTB test rig, a non-contact type pneumatic cylinder provides static loads to the test GFTB and a high-speed motor rotates a thrust runner up to the maximum speed of 80 krpm. Force sensor, torque arm connected to another force sensor, and thermocouples measures the applied static load, drag torque, and bearing temperature, respectively, for cooling flow rates of 0, 25, and 50 LPM at static loads of 50, 100, and 150 N. The test GFTB with the outer radius of 31.5 mm has six top foils supported on bump foil structures. During the series of tests, the transient responses of the bearing drag torque and bearing temperature are recorded until the bearing temperature converges with time for each cooling flow rate and static load. The test data show that the converged temperature decreases with increasing cooling flow rate and increases with increasing static load. The drag torque and friction coefficient decrease with increasing cooling flow rate, which may be attributed to the decrease in viscosity and lubricant (air) temperature. These test results suggest that an increase in cooling flow rate improves GFTB performance.

참고문헌 (8)

  1. Agrawal, G. L., "Foil Air", Gas Bearing Technology-an Overview, 1997, 78682~
  2. Balducchi, F., "Experimental Analysis of The Start-Up Torque of A Mildly Loaded Foil Thrust Bearing", ASME J. Tribol, 135(3), pp.31702-1~ (2013)
  3. 김태호, "가스 포일 스러스트 베어링의 하중지지 성능 및 구동 토크에 관한 실험적 연구", 한국트라이볼로지학회지, 31(4), pp.141~147 (2015), 한국트라이볼로지학회[DOI]
  4. LaTray, N., "Design of Novel Gas Foil Thrust Bearings and Test Validation in a High-Speed Test Rig", ASME J. Tribol, 142(7), pp.071803~ (2020)
  5. A Foil Thrust Bearing Test Rig for Evaluation of High Temperature Performance and Durability, "Dykas, B. D.", Army Research Laboratory, ~, pp.Report No. ARL-MR-0692 (2008)
  6. Dykas, B. D., "Factors Influencing the Performance of Foil Gas Thrust Bearings for Oil-Free Turbomachinery Applications", Doctor, pp.2006
  7. Lee, D., "Thermal Behavior of Radial Foil Bearings Supporting an Oil-Free Gas Turbine : Design of the Cooling Flow Passage and Modeling of the Thermal System", ASME J. Eng. Gas Turbines Power, 139(6), pp.061902~ (2017)
  8. 백건웅, "에어 포일 스러스트 베어링의 탑포일 경사면 형상이유동특성에 미치는 영향에 대한 수치해석 연구", 한국트라이볼로지학회지, 37(4), pp.117~124 (2021), 한국트라이볼로지학회[DOI]