본문 바로가기
KERD
논문KCI 등재

Experimental study on drag reduction characteristics through PIV visualization

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

The fluid force reduction characteristics with respect to changes in the diameter and gap ratios between two cylinders in a flow field were experimentally investigated by installing two cylinders in a circulating tank in which the Reynolds number was maintained at 10,000. The velocity vector fields were examined through flow visualization with particle image velocimetry (PIV). The temporal drag and lift variation measurement results showed that the magnitude of the drag and the amplitude of the lift were reduced when a smaller cylinder was present, as compared to the reference case without the smaller cylinder. The optimum gap ratio for which the drag reduction was the greatest differed with the diameter ratio of the two cylinders. The mean drag coefficient was the smallest when the diameter ratio was 0.4 and the gap ratio was 0.5. The mean absolute values of lift coefficient decreased near the optimum gap ratio in all cases, but this tendency was not observed as the gap ratio increased. PIV visualization showed the correlation between the velocity distribution and drag reduction characteristics of the stagnant region between the two cylinders.

Abstract

The fluid force reduction characteristics with respect to changes in the diameter and gap ratios between two cylinders in a flow field were experimentally investigated by installing two cylinders in a circulating tank in which the Reynolds number was maintained at 10,000. The velocity vector fields were examined through flow visualization with particle image velocimetry (PIV). The temporal drag and lift variation measurement results showed that the magnitude of the drag and the amplitude of the lift were reduced when a smaller cylinder was present, as compared to the reference case without the smaller cylinder. The optimum gap ratio for which the drag reduction was the greatest differed with the diameter ratio of the two cylinders. The mean drag coefficient was the smallest when the diameter ratio was 0.4 and the gap ratio was 0.5. The mean absolute values of lift coefficient decreased near the optimum gap ratio in all cases, but this tendency was not observed as the gap ratio increased. PIV visualization showed the correlation between the velocity distribution and drag reduction characteristics of the stagnant region between the two cylinders.

참고문헌 (9)

  1. B. Khalighi, "Experimental and computational study of unsteady wake flow behind a bluff body with a drag reduction device", SAE transactions, pp.1209~1222 (2001)
  2. T. Tamura, "The effect of turbulence on aerodynamic forces on a square cylinder with various corner shapes", Journal of Wind Engineering and Industrial Aerodynamics, 83(1-3), pp.135~145 (1999)
  3. W. C. Park, "Effect of the length of a splitter plate on drag reduction", Transactions of the Korean Society of Mechanical Engineers B, 17(11), pp.2809~2815 (1993)[DOI]
  4. Con J. Doolan, "Flat-Plate Interaction with the Near Wake of a Square Cylinder", The American Institute of Aeronautics and Astronautics Journal, 47(2), pp.475~478 (2009)
  5. 노기덕, "와법을 이용한 분리된 분할판을 가진 정방형주의 유동장 특성계산", 한국마린엔지니어링학회지, 37(2), pp.156~162 (2013), 한국마린엔지니어링학회[DOI]
  6. 노기덕, "분리된 분할판에 의한 정방형주의 항력감소", 한국마린엔지니어링학회지, 36(6), pp.808~813 (2012), 한국마린엔지니어링학회[DOI]
  7. T. Igarashi, "Drag reduction of a square prism by flow control using a small rod", Journal of Wind Engineering and Industrial Aerodynamics, 69, pp.141~153 (1997)
  8. H. Sakamoto, "Suppression of Fluid Forces Actiong on a Square Prism by Passive Control", Journal of Fluids Engineering, 119, pp.506~511 (1997)
  9. 노기덕, "직렬배열에 놓인 크기가 다른 정방형주의 유체력 저감특성", 대한기계학회논문집 B, 41(7), pp.435~443 (2017), 대한기계학회

이 간행물의 다른 논문 (7건)