선박 화재 시 선내의 연기농도가 승객의 피난시간에 미치는 영향
A Case Study on the Passengers' Evacuation Times according to the Fire Smoke Density On a Ship
1
조회
0
다운로드
9
인용
0
참고문헌
키워드
초록
Because ships are very isolated and independent objects when sailing on the ocean, if a fire and smoke occurs, nobody can be sure to escape safely from ship at the moment. On the focus of the relationship between the sight transmissivity by fire smoke density and the life safety, this study performs simulations and experiments, respectively. To evaluate the theoretical evacuation time, CFAST software which is known as a 2 zone model analysis tool is used, and the result is 54 seconds from ECR(Engine Control Room) exit to upper deck exit and 34 seconds from bosun store to upper deck exit. And totally 12 types of experiments are performed with other 10 persons per experiment. As the result, it is cleared that the low sight transmissivity leads to the low life safety and the obstruction which can be happen unexpectedly on the evacuation way on fire makes it worse. At the condition of the smoke density 0%, over 90% people arrive at upper deck exit safely. But with the transmissivity of 8%, 70%(from ECR) and 30%(from bosun store) among experiment persons of each can survive, and with same density and unexpected obstruction, the survival ratio goes down to only 20% and 10%.
Abstract
Because ships are very isolated and independent objects when sailing on the ocean, if a fire and smoke occurs, nobody can be sure to escape safely from ship at the moment. On the focus of the relationship between the sight transmissivity by fire smoke density and the life safety, this study performs simulations and experiments, respectively. To evaluate the theoretical evacuation time, CFAST software which is known as a 2 zone model analysis tool is used, and the result is 54 seconds from ECR(Engine Control Room) exit to upper deck exit and 34 seconds from bosun store to upper deck exit. And totally 12 types of experiments are performed with other 10 persons per experiment. As the result, it is cleared that the low sight transmissivity leads to the low life safety and the obstruction which can be happen unexpectedly on the evacuation way on fire makes it worse. At the condition of the smoke density 0%, over 90% people arrive at upper deck exit safely. But with the transmissivity of 8%, 70%(from ECR) and 30%(from bosun store) among experiment persons of each can survive, and with same density and unexpected obstruction, the survival ratio goes down to only 20% and 10%.
참고문헌 (12)
- International Convention for the Safety of Life at Sea, "International Maritime Organization" (2006), IMO
- 김원욱, "선박의 거주구역 화재시 연기거동 및 온도변화에 관한 시뮬레이션 연구", 한국마린엔지니어링학회 전기학술대회 논문집, pp.293~294 (2006)
- 한상국, "기관실화재 인명위험성평가에 관한 연구", 해양환경안전학회 추계학술대회, pp.283~289 (2006)
- M.E. Kim, "A study on the safe position from the local fire in the ship's engine-rooms", 한국마린엔지니어링학회 전기학술대회 논문집, pp.183~189 (2007)
- 김성윤, "선박용 미분무수 소화설비의 성능평가연구", 한국마린엔지니어링학회 전기학술대회 논문집, pp.155~156 (2006)
- [URL]
- Interim guideline for a simplified evacuation analysis on Ro-Ro passenger ship, "IMO", IMO MSC, pp.909~
- Recommendation on evacuation analysis for passenger ships and high-speed passenger craft, "IMO", ~, pp.FP46, WP.2.
- 조권회, "감문상" (2007), 실습선 한바다
- CFASTConsolidated Model of Fire Growth and Smoke Transport, "Richard D. Peacock", NIST, ~ (2005)
- 日本火災学会, "火災と建築" (2002), 共立出版株式会社
- Wonhwa Hong, "A study on the analysis of the evacuation safety at a high-rise apt. on fire", Proceedings of the 4th International Symposium on Architectural Interchanges in Asia (2006)