Enhancing fault ride through capability via diesel generator control in dynamic positioning vessels
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The current trend in dynamic positioning vessels involves using closed-bus tie systems, which aim to be more efficient by using fewer generators. However, this new setup brings challenges due to the potential for a single fault to disrupt the entire power systems. To address these challenges, the paper presents a strategy to control diesel generators and meet strict requirements for handling faults. Using extensive factory test data, simulation models are developed for individual governor and exciter systems. These models have an error margin of about 2.1%, showing their good alignment with real-world situations. With these simulation models, a thorough analysis of system stability is conducted. This analysis checks if the governor and automatic voltage regulator settings, validated by factory tests, can restore the system to normal operation. The investigation reveals that the frequency response remains stable even with short-circuit faults. However, the voltage response does not meet the ship's requirements. The paper investigates the reason behind this voltage problem due to an excessive integral controller gain value and implements changes to rectify it by adjusting controller parameters. By explaining the critical aspects of the voltage issue, the paper contributes to our understanding of strengthening closed-bus tie systems on dynamic positioning ships. The findings emphasize the importance of careful generator control to maintain a reliable power system, especially during faults.
Abstract
The current trend in dynamic positioning vessels involves using closed-bus tie systems, which aim to be more efficient by using fewer generators. However, this new setup brings challenges due to the potential for a single fault to disrupt the entire power systems. To address these challenges, the paper presents a strategy to control diesel generators and meet strict requirements for handling faults. Using extensive factory test data, simulation models are developed for individual governor and exciter systems. These models have an error margin of about 2.1%, showing their good alignment with real-world situations. With these simulation models, a thorough analysis of system stability is conducted. This analysis checks if the governor and automatic voltage regulator settings, validated by factory tests, can restore the system to normal operation. The investigation reveals that the frequency response remains stable even with short-circuit faults. However, the voltage response does not meet the ship's requirements. The paper investigates the reason behind this voltage problem due to an excessive integral controller gain value and implements changes to rectify it by adjusting controller parameters. By explaining the critical aspects of the voltage issue, the paper contributes to our understanding of strengthening closed-bus tie systems on dynamic positioning ships. The findings emphasize the importance of careful generator control to maintain a reliable power system, especially during faults.
참고문헌 (23)
- H. Fay, "Dynamic Positioning Systems" (1990), Technip
- US Coast Guard, "Recent Failures of Dynamic Positioning (DP) Systems on Mobile Offshore Drilling Units", ~ (2013)
- "Dynamic positioning (DP) vessel blackout"[URL]
- "Vessel rotation leads to loss of position – DP incident"[URL]
- ABS, "Guide for Dynamic Positioning Systems, DPS Guide", ~ (2013)
- DNV, "Dynamic Positioning Vessel Design Philosophy Guidelines", ~ (2012)
- ABB, "Generations: Safety and availability", ~ (2013)
- S. Kim, "Protection Coordination in Marine DC Power Distribution Networks", Ph. D., pp.2020
- A Method for Proving the Fault Ride-Through Capability of DP Vessels with HV Power Plant, "Marine Technology Society", ~ (2021)
- 김희문, "Study on the simulation of the dynamic characteristics of a marine diesel generator", 한국마린엔지니어링학회지, 45(6), pp.392~397 (2021), 한국마린엔지니어링학회[DOI]
- 이영찬, "Improved transient characteristics of output voltage of marine synchronous generator", 한국마린엔지니어링학회지, 42(2), pp.114~120 (2018), 한국마린엔지니어링학회[DOI]
- S. O. Settemsdal, "Fault ride-through testing of a LV power solution bluedrive plusC", Proceeding of Dynamic Positioning Conference, pp.1~15 (2016)
- S. Kim, "Protection coordination for reliable marine DC power distribution networks", IEEE Access, 8, pp.222813~222823 (2020)
- M. Roa, "Demonstration of fault ride through capability for closed bus operation on dynamic positioning vessels", 2016 Petroleum and Chemical Industry Technical Conference, pp.1~10 (2016)
- M. Roa, "Alternative Approaches for Demonstration of Fault Ride-through Capabilities on DP Vessels with Closed Bus Operation", Proceeding of Dynamic Positioning Conference, pp.1~8 (2016)
- S. Sarwito, "Transient voltage analysis for dynamic positioning closed bus electrical system on ship in laboratory scale", International Journal of Marine Engineering Innovation and Research, 4(3), pp.208~215 (2019)
- H. Saadat, "Power System Analysis" (1999), McGraw-Hill
- "UG-25+ Governor – Installation and Operation Manual", Product Manual 26579, ~ (2013)
- DNV GL, "Rules for Classification: Ships – Part 4 Systems and components, Chapter 8 Electrical installations", DNVGL-RU-SHIP-Pt4Ch8, ~ (2016)
- P. Kundur, "Power System Stability and Control" (1994), McGraw-Hill
- "Digital Excitation Systems – HDEC 2000 User’s Manual Rev", H, HD Hyundai Electric, ~ (2020)
- IEEE, "IEEE Recommended Practice for Excitation System Models for Power System Stability Studies", IEEE Std 421.5-2016, ~ (2016)
- J. Kim, "Intelligent Protection Scheme for Dynamic Positioning Vessels with Closed Bus-Tie Operation", The International Conference on Electrical Engineering 2022 (2022)
