Abstract

Purpose: Resonance frequency analysis (RFA), a non-invasive technique for the clinical measurement of implant stability, was investigated. Peri-implant bony defect may contribute to implant failure. This in vitrostudy evaluated the resonance frequencies according to various bony defects and determined whether the directional bone defect can affect the value of frequency analysis. Material and Method: Fifteen 3.75 mm in diameter and 10 mm in length, machined selftapping implant fixture were used. Twelve types of bone defects that have different horizontal and vertical dimensions were simulated. Embedded implants were attached to the dental surveyor. Then, the transducer was connected with the implant fixture and the ISQ value was measured at four different directions. Two-way analysis of variance and post hoc Sche ffe′test were performed at the 95% significance level. Results: The control group showed the highest ISQ value and 5 thread-360group had the lowest one. As the vertical exposure of implants in each angle was increased, the ISQ value was decreased. Although the horizontal exposure in each thread was increased, the ISQ value was not significantly decreased. Conclusion: Although the simulated defect type was different from each other, the ISQ value was similar among groups.

참고문헌 (19)

  1. "Osseointegrationand the edentulous predicament", 170, pp.439~444 (1991)
  2. "Assessment of implant stabilityas a prognostic determinant", 11, pp.491~501 (1988)
  3. "Quantitativedetermination of the stabilityof the implant-tissue interface using resonancefrequency analysis", 7, pp.261~267 (1996)
  4. "Determination of the elasticmodulus of resin based materials as afunction of resonance frequency duringpolymerisation", 15, pp.98~104 (1999)
  5. "The application of resonancefrequency measurements to studythe stability of titanium implants duringhealing in the rabbit tibia", pp.234~243 (1997)
  6. "Resonance frequency measurementsof implant stability in vivo", 8, pp.226~233 (1997)
  7. "Astudy of the measurement of the implantstability using resonance frequency analysis J Korean Academy of Prosthodontics2003", 41, pp.182~206 (2003)
  8. "mapping implant stability by resonancefrequency analysis", 24, pp.191~193 (1996)
  9. "In vitro comparative study betweenISQ and Periotest values on the implantstability measurements according tothe increased effective implant length JKorean Academy of Prosthodontics 2001", 39, pp.625~635 (2001)
  10. "Osseointegration in clinical Dentistry", pp.233~240 (1985), Branemark P-I Branemark P-I
  11. "The excessive lossof Branemark fixture in type Ⅳbone:a 5-year analysis", 62, pp.2~4 (1991)
  12. "Earlyfailures in 4 A study fromstage Ⅰsurgery to the connection of completedprostheses", 6, pp.142~146 (1991), 641 consecutively placedBrenemark dental implants
  13. "Success and failure rates of cylinder implantsin type Ⅳ bone", 64, pp.1085~1087 (1993)
  14. "The use of a new bioresorbablebarrier for guided bone regeneration in connectionwith implant installation", 5, pp.177~184 (1994)
  15. "Membraneinducedbone augmentation at titanium implants", 11, pp.273~281 (1991)
  16. "Clinical classificationof bone defects concerning theplacement of dental implants", 23, pp.147~155 (2003)
  17. "Assessment of implant stability in anosseointegration simulated model", 4, pp.360~363 (2002)
  18. "Periimplantbone tissue strains in cases of dehiscence:a finite element study", 13, pp.327~333 (2002)
  19. "Polymerization shrinkage of indexand pattern acrylic resins", 64, pp.684~688 (1990)