Evaluation of bone response by resonance frequency analysis of anodized implants

2

조회

0

다운로드

0

인용

0

참고문헌

주제분류치의학

초록

Abstract

Statement of problem. Resonance frequency analysis has been increasingly served as a noninvasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were Bra。nemark Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit).Test two implants were inserted in right side and control two in left side. ISQ values were measured using OsstellTM (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were 75.0 ± 3.4 and 68.7 ± 8.1 for control group. Mean and SD of ISQ values 12 weeks after implant insertion were 73.2 ± 4.7 for test group and 72.6 ± 3.9 for control group. There were no statistically significant differences between groups in ISQ values after 3months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

참고문헌 (11)

  1. "The interface zone of inorganicimplant in vivo;Titanium implants in bone", 11, pp.1~27 (1983)
  2. "Aspect of surface physics ontitanium implants" (1983)
  3. "The electrochemical behaviorof metallic implant materials as indicator of theirbiocompatibility", 21, pp.881~896 (1987)
  4. "In vitro corrosiontesting of titanium surgical implant alloys:an approachto understanding titanium release from implants", 13, pp.217~250 (1979)
  5. "Physico-chemical considerationsof titanium as a biomaterial", 9, pp.115~134 (1992)
  6. "Formation and characterizationof anodic titanium oxide films containing Caand P", 29, pp.65~72 (1995)
  7. "Theelectrochemical oxide growth behavior on titaniumin acid and alkaline electrolytes", 23, pp.329~46 (2001)
  8. "Assessment of implant stability as apognotic determinant", 11, pp.491~501 (1998)
  9. "Resonance FrequencyAnalysis:Measuring implant stability and osseointegration", 19, pp.493~502 (1998)
  10. "A study of the measurement of the implantstability using resonance frequency analysis" (2000), Dankook University
  11. "Requirements for ensuring a long-lastingdirect bone-to-implant anchorage in man" (1981), Branemark

관련 논문AI추천

이 간행물의 다른 논문 (5건)