논문KCI 등재
인상채득법이 임플랜트 주모형의 정확성에 미치는 영향
0
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
참고문헌 (26)
- Adell R, "Lekholm U"
- Han ET, "A comparativeanalysis of the accuracy of implant impression techniques by using strain gauge", 33, pp.539~ (1995)
- Burguete RL, "Johns RB"
- Misch CE. Contemporary implant dentistry, "Mosby Year Book", Inc
- Zarb GA, "Schmitt A. The longitudinalclinical effectiveness of osseo-integrated den-tal implants. The Tronto study. Part Ⅲ", pp.185~
- Humphries RM, "Bleom TJ. Theaccuracy of implant master casts con-structed from transfer impressions. Int J OralMaxillofac Implants 1990", pp.331~336
- "Jorneus L. Forces andmovements on Bra ¨ nemark implants. Int JOral Maxillofac Implants 1990", pp.241~247
- Zarb GA, "Osseointe-gration in Clinical Dentistry. Chicago", pp.117~128, Bra¨ nemark PI
- "Sones AD. Complications with osseointe-grated implants. J Prosthet Dent 1989", pp.581~585
- Barrett MG, "Burgess JO. Theaccuracy of six impression techniques forosseointegrated implants. J Prosthodont1993", pp.75~82
- Assif D, "Accuracy 70of implant impression techniques", 11, pp.216~222 (1996)
- "Carr AB. A comparison of impressiontechniques for a five implant mandibularmodel. Int J Oral Maxillofac Implants1991", pp.448~455
- Fenton A, "Schmitt A.Comparative accuracy of implant impres-sion procedures. Int J Periodont RestDent 1992", pp.113~121
- Phillips KM, "RubensteinJ. The accuracy of three implant impres-sion technique", pp.533~540
- Rodney J, "Harris W.Dimensional accuracy of two implant im-pression copings. J Dent Res 1991", pp.385~
- Misch CE, "Density of bone Effect ontreatment plans surgical approach healing and progressive loading", 10, pp.303~311 (1995)
- Worthington P, "Taylar TD.The Swedish system of osseo-integrated im-plants problems and complications en-countered during a 4-year trial period. IntJ Oral Maxillofac Implants 1987", pp.77~84
- Clelland NL, "Comparisonof strains transferred to a bone simulantbetween as cast and post soldered implant frameworks for a five implant supported fixed prosthesis", 5, pp.193~200 (1996)
- Jemt T, "vivo measurements of precisionfit involving implant supported prosthesesin the edentulous jaw", 11, pp.151~158 (1996)
- "Henry PJ. An alternative method for the pro-duction of accurate casts and occlusalrecords in osseointegrated implant reha-bilitation. J Prosthet Dent 1987", pp.694~697
- "Tautin FS. Impression making for os-seointegrated denture. J Prosthet Dent1985", pp.250~251
- Liou AD, "Nicholls JI"
- Wee AG, "Comparison of impression materials for direct multi implant impressions", 83, pp.323~331 (2000)
- Donovan TE, "Nicholls JI. Anevaluation of impression techniques for os-seointegrated implants. J Prosthet Dent1990", pp.444~7
- Carr AB, "The accuracy of implantverification casts compared with castsproduced from a rigid transfer copingtechnique", 5, pp.248~252 (1996)
- Lorenxoni M, "Comparisonof the transfer precision of three differentimpression materials in combination withtransfer caps for the Frialit2 system", 27, pp.629~638 (2000)
관련 논문AI추천
인상채득방법이 임플란트 주모형의 정확성에 미치는 영향김영오, 양홍서대한치과보철학회 · 대한치과보철학회지2004 · 제42권 제2호치과 임플랜트 인상채득 방법에 따른 주모형의 정확성에 대한 비교 연구류석민, 임주환, 임헌송, 조인호대한치과보철학회 · 대한치과보철학회지2002 · 제40권 제1호인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향이지혁, 조인호, 최유성대한턱관절교합학회 · 구강회복응용과학지2010 · 제26권 제4호임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향김석규, 박성화, 오갑용대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제1호임상적 방법을 이용한 내부연결 임플랜트에서 고정체수준 인상법의 정확도 평가최정한대한치과보철학회 · 대한치과보철학회지2006 · 제44권 제4호새로운 인상용 코핑을 이용한 임플란트 인상법의 정확성에 대한 3차원적 비교 연구고석민, 김세라, 김인수, 박성재, 이병옥대한턱관절교합학회 · 구강회복응용과학지2010 · 제26권 제3호
이 간행물의 다른 논문 (11건)
투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응박상원, 양홍서, 안석, 방몽숙, 박하옥pp. 1-9다양한 포스트와 코어의 물성이 근관치료된 치근의 응력분산에 미치는 영향이청희, 조진현pp. 10-19주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구박상원, 박하옥, 오수연, 양홍서, 방몽숙pp. 20-28CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도박인임, 이근우, 서준용pp. 29-39Periotest Value와 Implant Stability Quotient에 영향을 미치는 요소이영아, 이호용, 차인호, 한동후pp. 40-50
