A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.
Abstract
In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.
참고문헌 (20)
- Watt RG, "Adult Dental Health Survey 2009 : implications of findings for clinical practice and oral health policy", Br Dent J, 214, pp.71~75 (2013)
- Dye BA, "Trends in oral health status: United States, 1988-1994 and 1999-2004", Vital Health Stat 11, (248), pp.1~92 (2007)
- Bernhart G, "Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures", Clin Oral Investig, 16, pp.1031~1037 (2012)
- Al-Imam H, "Oral health-related quality of life and complications after treatment with partial removable dental prosthesis", J Oral Rehabil, 43, pp.23~30 (2016)
- Weaver JD, "Telescopic copings in restorative dentistry", J Prosthet Dent, 61, pp.429~433 (1989)
- Wenz HJ, "A telescopic crown concept for the restoration of the partially edentulous arch : the Marburg double crown system", Int J Prosthodont, 11, pp.541~550 (1998)
- Isaacson GO, "Telescope crown retainers for removable partial dentures", J Prosthet Dent, 22, pp.436~448 (1969)
- Böttger H, "The telescope system in dental prosthetics" (1961), Barth Verlag
- Güngör MA, "Parameters affecting retentive force of conus crowns", J Oral Rehabil, 31, pp.271~277 (2004)
- Wenz HJ, "A telescopic crown concept for the restoration of the partially edentulous arch : the Marburg double crown system", Int J Prosthodont, 11, pp.541~550 (1998)
- Weber H, "Spark erosion procedure : a method for extensive combined fixed and removable prosthodontic care", J Prosthet Dent, 69, pp.222~227 (1993)
- Jo LJ, "Spark erosion process : An overview", J Dent Implant, 1, pp.2~6 (2011)
- Nickenig HJ, "Survival and complication rates of combined tooth-implant-supported fixed and removable partial dentures", Int J Prosthodont, 21, pp.131~137 (2008)
- Sakar O, "Removable partial dentures: A practitioner’s manual", pp.195~208 (2016), Springer
- Akagawa Y, "A new telescopic crown system using a soldered horizontal pin for removable partial dentures", J Prosthet Dent, 69, pp.228~231 (1993)
- Thomason JM, "Two implant retained overdentures-a review of the literature supporting the McGill and York consensus statements", J Dent, 40, pp.22~34 (2012)
- Ishida K, "Prognosis of double crown-retained removable dental prostheses compared with clasp-retained removable dental prostheses : A retrospective study", J Prosthodont Res, 61, pp.268~275 (2017)
- Krennmair G, "Dental implants as strategic supplementary abutments for implant-tooth-supported telescopic crown-retained maxillary dentures : a retrospective follow-up study for up to 9 years", Int J Prosthodont, 20, pp.617~622 (2007)
- Mitrani R, "Posterior implants for distal extension removable prostheses : a retrospective study", Int J Periodont Restor Dent, 23, pp.353~359 (2003)
- Ben-Ur Z, "Rigidity of major connectors when subjected to bending and torsion forces", J Prosthet Dent, 62, pp.557~562 (1989)
