본문 바로가기
KERD
논문KCI 등재

상악 제1소구치의 교두각에 따른 전부도재관의 응력분포에 관한 삼차원유한요소법적 연구

0

조회

0

다운로드

0

인용

0

참고문헌

주제분류치의학

초록

Abstract

Statement of problem : Clinically, maxillary first premolar has a high risk of fracture. This is thought to be caused by the susceptible figure which the maxillary first premolar has. In other words, sharp cusp angles of the premolar is thought to influence this situation. Purpose : This study was to know stress distribution of all-ceramic crown according to the cusp angle. Material and Method : It was manufactured a three dimensional finite element model simplified maxillary first premolar, and then analyzed stress distribution when cusp angle was each 80., 90., 100., 110.and 120.. Results and conclusion : 1. The von Misses stress showed that stress decreases as cusp angle increases in the central groove of the occlusal surface. 2. It showed that maximum principal stress was centered at the region of the central groove of the occlusal surface and a region which the force was inflicted. And also it appeared high on the lingual and buccal side of finish line. 3. The X axis of normal stress was focused in the central groove of the occlusal surface. The Y axis normal stress appeared high in the central groove of the occlusal surface, buccal and lingual side. 4. The Stress near the finish line showed a low value compared with stress in the region of the central groove of the occlusal surface. 5. It shows that the most dangerous angle for tooth fracture was on 80.of the cusp angle and low on 120.of its.

참고문헌 (34)

  1. "Vita In-Ceram a new system forproducing aluminum oxide crown andbridge substructures", 16, pp.35~46
  2. "Die In-Ceram Aluminiumoxid-Keramiken innovativer dentalkelamischer Werkstoff", 37, pp.1597~ (1989)
  3. "Fracture surface analysis of dental ceramics", pp.430~440 (1990)
  4. "Fracture strength of all-pocelain Resin bonded bridges after testing in an artificialoral environment", pp.117~121 (1993)
  5. "Theeffect of tooth preparation design on thebreaking strength of Dicor crown", pp.327~340 (1990)
  6. "The effect of toothpreparation design on breaking strength ofDicor crowns", pp.159~164 (1990)
  7. "Dicor crown strengthimprovement due to bonding" (1987)
  8. "Clinical Examination of Leucite-Reinforced Glass-Ceramic Crowns(Empress)In General Pactice", 12, pp.124~125 (1999)
  9. "Movement of three removable partial dentureclasp assemblies under occlusal loading", pp.69~74 (1986)
  10. "Strain inmandibular alveolar bone during masticationin the rabbit", pp.667~675 (1977)
  11. "Analysis ofstresses in alveolar bone", pp.411~414 (1975)
  12. "Stress trajectories within the mandible underocclusal loads", pp.1297~1302 (1977)
  13. "Photoelastic analysis of stress patternson teeth and bone with attatchment retainersfor removable partial dentures", pp.21~28 (1981)
  14. "Effect of resilientlayer in a removable partial denturebase on stress distribution to the mandible", pp.17~20 (1980)
  15. "Relative magnitude of stress onabutment teeth with different retainers", pp.267~282 (1969)
  16. "Stresses from loadingdistal-extension removable partialdentures", pp.243~253 (1976)
  17. "A mathematical model of an invitro human mandible", pp.159~166 (1977)
  18. "Influence ofincisal length of ceramic and loading orientationon stress distribution in ceramiccrowns", pp.1371~1375 (1988)
  19. "Stress distributionin metal-ceramic crowns with a facialporcelain margin", pp.1493~1498 (1987)
  20. "Effects of labialmargin design on stress distribution of aporcelain-fused-to-metal crown", 1, pp.18~23 (1992)
  21. "The disclosure of cleavageand fracture lines in porcelain restorations" (1958)
  22. "Practical factors in buildingand firing characteristics of dentalporcelain" (1961)
  23. "A resume of ideas on porcelainjacket crown preparations", pp.1030~1039 (1934)
  24. "Contemporary fixed prosthodontics", mosby co, pp.1987~
  25. "Johnston’s modern practice in fixedprosthodontics" (1986)
  26. "Tylman’s theoryand practice of fixed prosthodontics", ishiyaku euroamerica inc, pp.1989~
  27. "The importance of an evenshoulder preparation in porcelain crowns", pp.305~314 (1972)
  28. "Relationship betweencompressive strength and cervicalshaping of the all-ceramic Cerestore crown", pp.147~152 (1987)
  29. "The effect oftooth preparation design on the breakingstrength of Dicor crowns", pp.159~168 (1990)
  30. "The effect of finishline form and luting agent on the breakingstrength of Dicor crowns", mu(zca), pp.286~290 (1993)
  31. "Astudy in the fracture strength of the IPSEmpressceramic crown according to margintype", 35, pp.296~307 (1997)
  32. "Fractureresistance of castable ceramic crowns(abstract)", 68, pp.235~ (1989)
  33. "Shearbond strength of resin to etched porcelain(abstract)", 64, pp.296~ (1985)
  34. "Maximale Kaukraftals Berechnungsfaktor zahntechnischerKonstruktionen", 31, pp.55~60 (1983)

관련 논문AI추천

치주 지지가 감소된 소구치에서 포스트가 치근 응력 분포에 미치는 영향에대한 3차원 유한요소법적 연구김한성, 오남식, 유재흥, 정혜진대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제5호임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구박원희, 이영수대한치과보철학회 · 대한치과보철학회지2005 · 제43권 제1호상악중절치에서 전부도재관의 finish line형태에 따른 파절강도와 응력 분포에 관한 연구기태석, 김계순, 김유리, 동진근, 이진한대한치과보철학회 · 대한치과보철학회지2003 · 제41권 제4호하악피개의치에서 임플랜트의 식립각도에 따른칸틸레버 길이의 감소효과가 응력분포 양상에 미치는 영향 -삼차원 유한요소법을 이용한 분석-권긍록, 박준수, 우이형, 이성복대한치과보철학회 · 대한치과보철학회지2007 · 제45권 제4호구치의 경사도와 회전정도가 발치공간 폐쇄시 치근막의 응력분포와 치아의 초기이동에 미치는 영향에 대한 3차원 유한요소법적 연구권대우, 손우성, 양훈철대한치과교정학회 · 대한치과교정학회지2004 · 제34권 제5호구치부 부분 무치악 결손에서 유용한 세 가지 임프란트 수복법들의 응력분산에 관한 3차원 유한요소법적 비교연구김일규, 류승현, 변효인, 손충렬, 윤영아, 이성호, 최진호, 한예숙대한구강악안면외과학회 · 대한구강악안면외과학회지2004 · 제30권 제3호

이 간행물의 다른 논문 (9건)