하악구치부에서 Bicon 임플란트에 의해 지지되는 고정성 국소의치의 광탄성 응력분석
A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH BICON IMPLANTS ON MANDIBULAR POSTERIOR AREA
0
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
Statement of problem: Several prosthetic options are available for the restoration of multiple adjacent implants. A passively fitting prosthesis has been considered a prerequisite for the success and maintenance of osseointegration. Passivity is a particular concern with multiple implants because of documented inaccuracies in the casting and soldering process. One way to avoid this problem is to restore the implants individually, however, the restorations of individual adjacent impants requires careful adjustment of interproximal contacts. Purpose: The purpose of this study was to compare the stress distribution pattern and amount surrounding Bicon implants with individual crowns and splinted restorations. Material and method: A photoelastic model of a human partially edentulous left mandible with 3 Bicon implants(4×11 mm) was fabricated. For non-splinted restorations, individual crowns were fabricated on 3 abutments (4.0×6.5 ㎜, 0。, 2.0 ㎜post, Bicon Inc., Boston, USA) After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal (8 ㎛shim stock drags without tearing), medium(40 ㎛), and heavy(80 ㎛). Splinted 3-unit fixed partial dentures were fabricated and cemented to the model. Changes in stress distribution under simulated non-loaded and loaded conditions(7.5, 15, 30 lb) were analyzed with a circular polaricope. Results: 1. Stresses were distributed around the entire body of fin in Bicon implants. 2. Splinted restorations were useful for distribution of stress around implants especially with higher loads. 3. By increasing the contact tightness between the individually restored three implants, the stress increased in the coronal portion of implants. Conclusions: Ideal adjustment of the contact tightness was important to reduce the stresses around individually restored Bicon implants.
참고문헌 (26)
- "Mechanical loading of Bra ¨nemark implantsaffects interfacial bone modeling andremodeling", 9, pp.345~60
- "Forces andmoment on Bra ¨nemark implants", 4, pp.241~7 (1989)
- "Bending overload and implant fracture:a retrospective clinical analysis", 10, pp.326~34 (1995)
- "The influence of controlledocclusal overload on peri-implant tissue", 13, pp.677~83 (1998)
- "The influence of controlled occlusaloverload on peri-implant tissue", 15, pp.425~31 (2000)
- "A finiteelement survey of eleven endosseousimplants J Prosthet Dent", 63(4), pp.457~65
- "Alternative materials for three endosseousimplantsJ Prosthet Dent 1989Jun", pp.717~22
- "Clinical rationale for tooth stabilizationand splinting", 43, pp.1~6 (1999)
- "Reactive force distributionsfor teeth when loaded singly andwhen used as fixed partial denture abutments", 42(4), pp.411~6
- "Influence of restoration type on stress distributionin bone around implants:a threedimensionalfinite element analysis", 13, pp.82~90 (1998)
- "A photoelastic study to determinethe location of the nonrigid connector inafive-unit intermediate abutment prosthesisJ Prosthet Dent 1987", pp.454~7
- "Restorative-based treatmentplaning:determinig adequate support forimplant-retained fixed restoration", 5, pp.179~84 (1996)
- "Fixture design and overload influencemarginal bone loss and fixture successin the Branemark system", 3, pp.104~11 (1992)
- "Analysisof load transfer and stress distribution byan implant-supported fixed partial denture", 75(3), pp.285~91 (1996)
- "Comparative accuracy of implant impressionprocedures", 12(2), pp.112~21 (1992)
- "An alternative tosplinting multiple implants: use of the ITI system", 7(2), pp.114~9 (1998)
- "The rotational aspect ofmandibular flexure", 64, pp.483~5 (1990)
- "Effect of splinting and interproximal contacttightness on load transfer by implantrestorations", 87(5), pp.528~35 (2002)
- "Deformation ofthe human mandible during simulatedtooth clenching", 73, pp.56~66 (1994)
- "Mandibular deformationin subjects with osseointegratedimplants", pp.319~28
- "Biomechanical concerns withfixed partial dentures involving implants", 2(4), pp.221~42
- "Finite elementstress analysis on the effect ofsplinting in fixed partial dentures", 81(6), pp.721~8 (1999)
- "Experimental stress analysis of dentalrestorations Structural design andstress analysis of fixed partial dentures", (abstract available), pp.177~86
- "The newconcept of ITI hollow -cylinder and hollowscrewimplants", pp.161~72
- "Comparison ofperi-implant stresses transmitted by fourcommercially available osseointegratedimplants", 9(3), pp.221~30 (1989)
- "The locking taperattachment for implant abutments: useand reliability", 5(4), pp.257~61 (1996)