논문KCI 등재
교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연구
2
조회
0
다운로드
0
인용
0
참고문헌
주제분류치의학
초록
Abstract
Conclusion: According to the research, the removal torque values were decre ased at 7
참고문헌 (24)
- "A study oforthodontic anchorage possibilites in basalbone", pp.406~417
- "Studies on the efficacy of implants asorthodontic anchorage", pp.311~317
- "Osseous adaptation498to continuous loading of rigid endosseousimplants", pp.95~111
- "Rigidimplant anchorage to close a mandiblefirst molar extraction site", pp.79~87
- "Rigid endosseous implants for ortho-dontic orthopedic anchorage", pp.247~255
- "Osseointegrated titaniumimplants for maxillofacial protraction inmonkeys", pp.285~295
- "Uses of implantsin Orthodontics", pp.539~550
- "The use of titaniumfixtures for intraoral anchorage to facilitateorthodontic tooth movement", pp.338~344
- "A new device ofabsolute anchorage for orthodontics", 107, pp.251~259 (1995)
- "Intrusion anchoragepotential of teeth versus rigid endosseousimplants: A clinical and radiographicevaluation", 107, pp.115~120 (1995)
- "The effect of dentalorthopedic force to implants on bone tis-sue before complete osseointegratio", 28, pp.453~459 (1998)
- "The effect early load-ing on the direct bone to implant surfacecontact of the orthodontic osseointegratedtitanium", 31, pp.173~185 (2001)
- "Mini-implant for orthodonticanchorage", 31, pp.763~767 (1997)
- "Miniscrewas orthodontic anchorage: A preliminaryreport", 13, pp.201~209 (1998)
- "A new protocol of the slidingmechanics with micro-implant anchor-age(M.I.A.)", 30, pp.677~685 (2000)
- "Clincal study on success rate ofmicroscrew implants for orthodontic anchor-age", 33, pp.151~156 (2003)
- "Integrationof screw implants in the rabbit A 1-yr fol-low up of removable torque of titaniumimplants", pp.69~75
- "Bone tissue interface", 52, pp.804~809 (1998)
- "Resonance frequency mea-surement of implant stability in vivo onimplants with a sandblasted and acid-etchedsurface", 18, pp.641~665 (2003)
- "Influence ofimplant diameters on the integration ofscrew implant: An experimental studyin rabbits", 18, pp.687~692 (1997)
- "Influence of implant taper on the prima-ry and secondary stability of osseointegratedtitanium implants", 15, pp.474~480 (2004)
- "Contemporary implant dentistry", pp.311~349 (2000), Seoul: Published by NaraePublishing Co.
- "Three dimensional finite elementmethod for stress distribution on thelength a diameter of orthodontic miniscrewand cortical bone thickness", 33, pp.11~20 (2003)
- "Assessment of implant stabilityas a prognostic determinant", 11, pp.491~501 (1998)
관련 논문AI추천
교정용 미니임플랜트의 이중 피치와 직경의 차이가 삽입 및 제거 토크에 미치는 영향 평가김종완, 김태우, 이신재, 장영일, 조일식대한치과교정학회 · 대한치과교정학회지2006 · 제36권 제4호교정치료 고정원으로서 Microscrew implants의 성공율에 대한 임상적 연구박효상대한치과교정학회 · 대한치과교정학회지2003 · 제33권 제3호고정원을 위한 micro-implant 매식시drilling 유무에 따른 안정성에 관한 연구김종완, 장영일대한치과교정학회 · 대한치과교정학회지2002 · 제32권 제2호교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크윤태민, 차정열, 황충주대한치과교정학회 · 대한치과교정학회지2008 · 제38권 제1호구내고정원을 이용한 교정 치료중 minscrew 탈락에 관한 연구심광섭, 우순섭, 유임학, 정순태, 허영성, 황경균대한구강악안면외과학회 · 대한구강악안면외과학회지2003 · 제29권 제2호교정용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교윤순동, 임성훈대한치과교정학회 · 대한치과교정학회지2009 · 제39권 제2호
이 간행물의 다른 논문 (11건)
불산 식각 농도 및 시간이 lithium disilicate 도재와레진시멘트의 전단결합강도에 미치는 영향서재민, 박찬운, 안승근pp. 407-418도재 수리시스템에 따른 도재와 복합레진의 전단결합강도김경규, 이정렬, 김영수, 신상완pp. 419-430타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교임현필, 양홍서, 방몽숙, 박하옥, 박상원, 이영재pp. 431-443하악피개의치에서 임플랜트의 식립각도에 따른칸틸레버 길이의 감소효과가 응력분포 양상에 미치는 영향 -삼차원 유한요소법을 이용한 분석-이성복, 박준수, 권긍록, 우이형pp. 444-456수종의 실란처리 유리섬유를 첨가한 의치상용 레진의강도변화 및 마모전?후 표면성상분석김명주, 김창회, 임영준, 이상일, 윤석대pp. 457-468