총 IgE의 신속한 정량 측정을 위한 ImmuneCheck IgE의 임상적 유용성

Clinical validation of ImmuneCheck IgE for the rapid detection of serum total IgE

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류소아과학

초록

Purpose: Conventional serum IgE assay was costly, required the skills of expert, and relied heavily on expensive equipment. Quantitative measurement of total IgE using Point of Care Test (POCT) device can be the solution for these limitations. This study evaluated and validated the reproducibility of ImmuneCheck IgE. Methods: This study included 120 patients of allergic diseases such as allergic rhinitis, asthma, drug allergy, food allergy, atopic dermatitis, or anaphylaxis . The reliability of POCT ImmuneCheck IgE was evaluated by comparing results from the naked eye and from the Q-Reader. Intratest reproducibility and intertest correlation were analyzed using intraclass correlation coefficient (ICC). Results: Of the 120 enrolled patients, 51 were males and 69 were females. The ages ranged from 19 to 84 years, with an average age of 51.5 years. The concentration of serum total IgE measured by Phadia ImmunoCAP IgE ranged from 5.95 to 5,000 IU/mL. ICC for Intratest reproducibility of ImmuneCheck IgE by naked eye and by Q-Reader were 0.991 (P<0.001) and 0.989 (P<0.001), respectively. In addition, intertest correlation between ImmuneCheck IgE and Phadia ImmunoCAP IgE results of naked eye and Q-Reader were 0.968 (P<0.001) and 0.948 (P<0.001), respectively. Conclusion: The ImmuneCheck IgE was reproducible and highly correlated with conventional Phadia ImmunoCAP IgE assay. This result suggests that ImmuneCheck IgE can be a useful tool for rapid and precise detection of total IgE.

Abstract

Purpose: Conventional serum IgE assay was costly, required the skills of expert, and relied heavily on expensive equipment. Quantitative measurement of total IgE using Point of Care Test (POCT) device can be the solution for these limitations. This study evaluated and validated the reproducibility of ImmuneCheck IgE. Methods: This study included 120 patients of allergic diseases such as allergic rhinitis, asthma, drug allergy, food allergy, atopic dermatitis, or anaphylaxis . The reliability of POCT ImmuneCheck IgE was evaluated by comparing results from the naked eye and from the Q-Reader. Intratest reproducibility and intertest correlation were analyzed using intraclass correlation coefficient (ICC). Results: Of the 120 enrolled patients, 51 were males and 69 were females. The ages ranged from 19 to 84 years, with an average age of 51.5 years. The concentration of serum total IgE measured by Phadia ImmunoCAP IgE ranged from 5.95 to 5,000 IU/mL. ICC for Intratest reproducibility of ImmuneCheck IgE by naked eye and by Q-Reader were 0.991 (P<0.001) and 0.989 (P<0.001), respectively. In addition, intertest correlation between ImmuneCheck IgE and Phadia ImmunoCAP IgE results of naked eye and Q-Reader were 0.968 (P<0.001) and 0.948 (P<0.001), respectively. Conclusion: The ImmuneCheck IgE was reproducible and highly correlated with conventional Phadia ImmunoCAP IgE assay. This result suggests that ImmuneCheck IgE can be a useful tool for rapid and precise detection of total IgE.

참고문헌 (17)

  1. Stone KD, "IgE, mast cells, basophils, and eosinophils", J Allergy Clin Immunol, 125(2 Suppl 2), pp.S73~S80 (2010)
  2. Schroeder HW Jr, "Structure and function of immunoglobulins", J Allergy Clin Immunol, 125(2 Suppl 2), pp.S41~S52 (2010)
  3. Bonilla FA, "Pharmacokinetics of immunoglobulin administered via intravenous or subcutaneous routes", Immunol Allergy Clin North Am, 28, pp.803~819 (2008)
  4. Kelly BT, "Immunoglobulin E, what is it good for?", Ann Allergy Asthma Immunol, 116, pp.183~187 (2016)
  5. Lawrence MG, "Half-life of IgE in serum and skin: consequences for anti-IgE therapy in patients with allergic disease", J Allergy Clin Immunol, 139, pp.422~428 (2017)
  6. Johansson SG, "The discovery of immunoglobulin e and its role in allergy", Chem Immunol Allergy, 100, pp.150~154 (2014)
  7. Sanjuan MA, "Role of IgE in autoimmunity", J Allergy Clin Immunol, 137, pp.1651~1661 (2016)
  8. Huang Y, "Regulation of IgE Responses by γδ T Cells", Curr Allergy Asthma Rep, 15, pp.13~ (2015)
  9. 박혜정, "Prevalence of Self-reported Allergic Diseases and IgE Levels: A 2010 KNHANES Analysis", Allergy, Asthma & Immunology Research, 9(4), pp.329~339 (2017), 대한천식알레르기학회
  10. Greenberger PA, "Allergic bronchopulmonary aspergillosis", J Allergy Clin Immunol Pract, 2, pp.703~708 (2014)
  11. Kornmann O, "Omalizumab in patients with allergic (IgE-mediated) asthma and IgE", bodyweight combinations above those in the initially approved dosing table, 2014, pp.28, 149~153
  12. Baker DL, "Response to Becher and Strohner comment regarding Baker DL et al. Evaluation of two commercial omalizumab", free IgE immunoassays: implications of use during therapy, 2014, pp.30, 913~922
  13. Gould HJ, "IgE in allergy and asthma today", Nat Rev Immunol, 8, pp.205~217 (2008)
  14. Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
  15. Nichols JH, "Point of care testing", Clin Lab Med, 27, pp.893~908 (2007)
  16. Price CP, "Point of care testing", BMJ, 322, pp.1285~1288 (2001)
  17. Hirsch J, "Point-of-care testing apparatus. Measurement of coagulation", Anaesthesia, 56, pp.760~763 (2001)

관련 논문AI추천

이 간행물의 다른 논문 (7건)