본문 바로가기
KERD
논문KCI 등재

사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발

Development of Bib Pants Design and Pattern for Cycling Smart Wear

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류생활과학

초록

In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S—T8' > 'S—T10' > 'S—L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S—L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Abstract

In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S—T8' > 'S—T10' > 'S—L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S—L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

참고문헌 (26)

  1. Asplund, C., "Knee pain and bicycling : Fitting concepts for clinicians", The Physician and sportsmedicine, 32(4), pp.23~30 (2004)
  2. Borgers, A., "Etiology of knee pain in elite cyclists : A 14-month consecutive case series", Acta Orthopaedica Belgica, 86(2), pp.262~271 (2020)
  3. Brukner, P., "Brukner & Khan’s Clinical Sports Medicine" (2021), McGraw-Hill Education
  4. Gardner, J. K., "Effects of toe-in angles on knee biomechanics in cycling of patients with medial knee osteoarthritis", Clinical Biomechanics, 30(3), pp.276~282 (2015)
  5. Han, W., "Sport science : Cycle fitting and Sport science", Sport Science, 124, pp.46~55 (2013)
  6. Innopolis, "스마트의류시장", Innopolis, ~ (2020)
  7. 정제현, "8주간의 스피닝 운동이 중년 비만 여성의 신체조성, 건강관련 체력과 혈관탄성도에 미치는 영향", 석사, 교육학과 체육교육전공, pp.2013
  8. Kang, A., "Biomechanical assessment of lumbar behavior in relation to saddle height variation during cycling exercise", Proceedings of RESKO Academic Symposium, pp.168~170 (2013), Rehabilitation Engineering And Assistive Technology Society of Korea
  9. 이형국, "고정식 자전거 운동 자세에 따른 운동부하강도와 근육 활성도 발현의 비교", 한국발육발달학회지, 28(1), pp.1~6 (2020), 한국발육발달학회[DOI]
  10. 이현주, "스마트 디바이스의 세대별 사용자 경험 변화 연구", 한국콘텐츠학회 논문지, 19(3), pp.252~260 (2019), 한국콘텐츠학회[DOI]
  11. 이재경, "스마트 의류의 제품 사례 연구-스마트 의류 특허출원 기술을 중심으로-", 한국의류학회지, 45(1), pp.28~45 (2021), 한국의류학회[DOI]
  12. MacAuley, D., "In a guide to cycling injuries : Prevention& treatment" (1996), Bicycle Books
  13. Mann, S., "Smart clothing : The wearable computer and wearcam", Personal Technologies, 1, pp.21~27 (1997)
  14. Marsden, M., "Lower back pain in cyclists: A review of epidemiology, pathomechanics and risk factors", International Sport Med Journal, 11(1), pp.216~225 (2010)
  15. Min, S., "System of prevention injury during cycle excercising sensors", Proceedings of the Korean Society of Computer Information Conference, pp.311~312 (2021), Korean Society of Computer Information
  16. Nachemson, A. L., "The lumbar spine an orthopaedic challenge", Spine, 1(1), pp.59~71 (1976)
  17. 박현정, "선수용 사이클 웨어의 착용 실태 조사 - 국내 남자 고등학교 사이클 선수를 중심으로 -", 한국의류산업학회지, 17(4), pp.597~603 (2015), 한국의류산업학회
  18. Trends in smart clothing development and commercialization in global markets, "Park, S.", Weekly KDB, 4~7 (2019)
  19. Polga, D. J., "Measurement of in vivo intradiscal pressure in healthy thoracic intervertebral discs", Spine, 29(12), pp.1320~1324 (2004)
  20. 손경환, "부상예방을 위한 효율적 자전거 피팅 방법에 관한 고찰(자전거 피팅 시스템 개발을 위해)", 한국컴퓨터정보학회논문지, 25(3), pp.145~154 (2020), 한국컴퓨터정보학회[DOI]
  21. Short, K. R., "Impact of aerobic exercise training on age-related changes in insulin sensitivity and muscle oxidative capacity", Diabetes, 52(8), pp.1888~1896 (2003)
  22. Tao, X., "Smart fibres, fabrics and clothing" (2001), Woodhead
  23. Turpin, N. A., "Cycling biomechanics and its relationship to performance", Applied Sciences, 10(12), pp.4112~ (2020)
  24. Van Hoof, W., "Comparing lower lumbar kinematics in cyclists with low back pain (flexion pattern) versus asymptomatic controls: Field study using a wireless posture monitoring system", Manual therapy, 17(4), pp.312~317 (2012)
  25. Wilke, H. J., "New in vivo measurements of pressures in the intervertebral disc in daily life", Spine, 24(8), pp.755~762 (1999)
  26. 유영복, "스마트 의류의 기술동향: 특허정보분석을 중심으로", 한국콘텐츠학회 논문지, 13(4), pp.440~451 (2013), 한국콘텐츠학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (9건)