An On-Chip Cockcroft-Walton Switched-Capacitor Converter Using Split-Phase Control for Improved Soft-Charging with 9.72 Conversion Gain
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This work proposes a switched-capacitor (SC) converter for high voltage generation required for medical ultrasound imaging system. The SC converter is quite advantageous for the implementation of an integrated circuit (IC) in terms of area. Besides, the SC converter has relatively less conduction loss than an inductive DC-DC boost converter. For these reasons, the SC converter is suitable for generating high voltages in ICs. However, the power loss of the SC converter can be analyzed by dividing it into three major losses. This work analyzes these losses and applies techniques to reduce them in order to improve the conversion gain and power efficiency. As a result, an on-chip Cockcroft-Walton SC converter using split-phase control for improved soft-charging with conversion gain 9.72 and power efficiency 70.1% suitable for the portable ultrasound imaging device is implemented. However, the measurement results of this study were worse than the simulation results due to mismatched control clock.
Abstract
This work proposes a switched-capacitor (SC) converter for high voltage generation required for medical ultrasound imaging system. The SC converter is quite advantageous for the implementation of an integrated circuit (IC) in terms of area. Besides, the SC converter has relatively less conduction loss than an inductive DC-DC boost converter. For these reasons, the SC converter is suitable for generating high voltages in ICs. However, the power loss of the SC converter can be analyzed by dividing it into three major losses. This work analyzes these losses and applies techniques to reduce them in order to improve the conversion gain and power efficiency. As a result, an on-chip Cockcroft-Walton SC converter using split-phase control for improved soft-charging with conversion gain 9.72 and power efficiency 70.1% suitable for the portable ultrasound imaging device is implemented. However, the measurement results of this study were worse than the simulation results due to mismatched control clock.
참고문헌 (12)
- M. Forouzesh, "QQQQStep-Up DC–DC Converters: A Comprehensive Review of Voltage Boosting Techniques, Topologies, and Applications", IEEE Transactions on Power Electronics (2017)
- MAY, Ryan, "Analysis of soft charging switched capacitor power converters", Master, pp.2014
- M. D. Seeman, "Analysis and Optimization of Switched-Capacitor DC–DC Converters", IEEE Transactions on Power Electronics, 23(2), pp.841~851 (2008)
- X. Qian, "A bone-guided cochlear implant CMOS microsystem preserving acoustic hearing", Symposium on VLSI Circuits (2017)
- Z. Chen, "A Single-Chip Solar Energy Harvesting IC Using Integrated Photodiodes for Biomedical Implant Applications", IEEE Transactions on Biomedical Circuits and Systems, 11(1), pp.44~53 (2017)
- H. Tang, "11.8 Integrated ultrasonic system for measuring body-fat composition", EEE International Solid-State Circuits Conference - Digest of Technical Papers, pp.1~3 (2015)
- Y. Lei, "A General Method for Analyzing Resonant and Soft Charging Operation of Switched-Capacitor Converters", IEEE Transactions on Power Electronics, 30(10), pp.5650~5664 (2015)
- Y. Lei, "Split-Phase Control: Achieving Complete Soft Charging Operation of a Dickson Switched-Capacitor Converter", IEEE Transactions on Power Electronics, 31(1), pp.770~782 (2016)
- M. D. Seeman, "A design methodology for switchedcapacitor DC-DC converters", Ph.D, pp.2009
- Abdi, Alfian, "A High-Voltage Generation Charge-Pump IC using Input Voltage Modulated Regulation for Neural Implant Devices", TCAS II (2019)
- Ismail.Y, "A 34V charge pump in 65nm bulk CMOS technology", ISSCC (2014)
- Marcy, "A 1.2 MHz, 25 V to 100 V GaN-based resonant Dickson switched-capacitor converter with 1011 W", in3 (61.7 kW, APEC, pp.2015[DOI]
