나사못을 이용한 수술 후 발생한 척추경 나사못의 해리와 골밀도의 관계
The Relationship between the Pedicle Screw Loosening and Bone Mineral Density after Transpedicular Spinal Instrumentation
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: We have analyzed relationship between pedicle screw loosening and bone mineral densitiy (BMD) after spinal arthrodesis with pedicle screw. Materials and Methods: We have chosen 31 cases that had screw loosening radiologically on the follow up X-ray among the patients who underwent spinal arthrodesis with pedicle screws, and compared Saville’s index that was measured by lateral view of preoperative X-ray with Dual energy X-ray absortiometry (DEXA) score. Results: There were 31 cases (5.34%) with screw loosening among 580cases operated with pedicle screws. According to Saville’s index of osteoporosis, 4 cases were grade I, 11 cases were grade II, and 16 cases were grade III, showing statistically significant difference (P<0.05). Each average score of the BMD (g/cm2) of anteroposteior aspect of lumbosacral spine that was measured by DEXA in grade I, II, III by Saville’s index were 0.881, 0.782, 0.708. The group with higher Saville’s index had the lower score of BMD (correlation coefficient -0.65). Conclusions: Osteoporosis is the preoperative risk factor that may occur screw loosening. It is necessary to measure objective and accurate score of BMD, provide additional treatment for osteoporosis and supplementary procedure that increases the stability of screws in the patients of grade II and grade III by Saville’s index.
Abstract
Objectives: We have analyzed relationship between pedicle screw loosening and bone mineral densitiy (BMD) after spinal arthrodesis with pedicle screw. Materials and Methods: We have chosen 31 cases that had screw loosening radiologically on the follow up X-ray among the patients who underwent spinal arthrodesis with pedicle screws, and compared Saville’s index that was measured by lateral view of preoperative X-ray with Dual energy X-ray absortiometry (DEXA) score. Results: There were 31 cases (5.34%) with screw loosening among 580cases operated with pedicle screws. According to Saville’s index of osteoporosis, 4 cases were grade I, 11 cases were grade II, and 16 cases were grade III, showing statistically significant difference (P<0.05). Each average score of the BMD (g/cm2) of anteroposteior aspect of lumbosacral spine that was measured by DEXA in grade I, II, III by Saville’s index were 0.881, 0.782, 0.708. The group with higher Saville’s index had the lower score of BMD (correlation coefficient -0.65). Conclusions: Osteoporosis is the preoperative risk factor that may occur screw loosening. It is necessary to measure objective and accurate score of BMD, provide additional treatment for osteoporosis and supplementary procedure that increases the stability of screws in the patients of grade II and grade III by Saville’s index.
참고문헌 (21)
- Bucher HH, "A method of spinal fusion", J Bone Joint Surg, 41B, pp.248~259 (1959)
- Cortrel Y, "The use of the pedicle screw and universal instrumentation for spinal fixation", Paper presented to the AO Trauma Course (1985)
- Okuyama K, "Stability of transpedicular screwing for the osteoporosis spine", Spine, 18, pp.2240~2245 (1993)
- Roy-Camille R, "Plating or thoracic, thoracolumbar and lumbar injuries with pedicle screw plates", Orthop Clin North Am, 17, pp.147~159 (1986)
- Wittenberg RH, "Importance of bone mineral density in instrumented spinal fusion", Spine, 16, pp.647~652 (1991)
- Singh M, "Changes in trabecular pattern of the upper end of the femur as an index of osteoporosis", J Bone Joint Surg Am, 52, pp.457~467 (1970)
- Saville PD, "A quantitative approach to simple radiographic diagnosis of osteoporosis; It's application to the osteoporosis of rheumatoid arthritis", Arthritis Rheum, 10, pp.416~422 (1967)
- Kim NH, "The effect of bone mineral density on instrumented spine fusion", J of Korean Spine Surg, 2, pp.133~139 (1994)
- Asher MA, "Anthropometric studies of the human sacrum relating to dorsal transacral implant design", Clin Orthop Relat Res, 203, pp.58~62 (1986)
- Steffee AD, "Segmental spine plates with pedicle screw fixation. A new internal fixation device for disorder of the lumbar and thoracolumbar spine", Clin Orthop Relat Res, 203, pp.45~53 (1986)
- Zucherman J, "Early results of spinal fusion variable spine plating system", Spine, 13, pp.570~579 (1988)
- Boos N, "Survivorship analysis of pedicular fixation systems in the treatment of degenerative disorders of the lumbar spine: A comparison of Cotrel-Dubousset instrumentation and the AO internal fixator", J Spinal Disord, 5, pp.403~409 (1992)
- Colemont J, "Stabilization of the lumbosacral spine in postlaminectomy syndromes. Technique and 2-year results", Acta Orthop Belg, 57, pp.247~254 (1991)
- Davne SH, "Complications of lumbar spinal fusion with transpedicular instrumentation", Spine, 17, pp.S184~S189 (1992)
- Ebelke DK, "Survivorship analysis of VSP spine instrumentation in the treatment of thoracolumbar and lumbar burst fracture", Spine, 16, pp.S428~S432 (1991)
- Esses SI, "Operative treatment of spinal fractures with the AO internal fixator", Spine, 16, pp.S146~S150 (1991)
- Marchesi DG, "Application and results of the AO internal fixation system in nontraumatic indications", Spine, 16, pp.S162~S169 (1991)
- Cha SI, "A study on change of the vertebral pedicle and mechanical strengths after screw insertion", J of Korean Orthop Surgery, 31, pp.42~51 (1996)
- Soshi S, "An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine", Spine, 16, pp.1335~1341 (1991)
- Goldsmith NF, "Bone mineral in the radius and vertebral osteoporosis in insured population", J Bone Joint Surg, 55A, pp.1276~1293 (1973)
- Kang CN, "Correlation between Saville’s index and bone mineral density measured by the lateral Dual X-ray absorptiometry and clinical usefulness of the Saville’s index", J of Korean Orthop, 30, pp.1604~1606 (1995)
