Electrochemical Behavior of Udenafil on Glass Carbon Electrode
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The voltammetric behavior of udenafil on glassy carbon electrode was studied using cyclic, linear sweep and square-wave (SW) techniques. Udenafil showed an irreversible oxidation behavior in aqueous buffer solutions containing 30% (v/v) acetonitrile over the pH range of 2 to 6. The oxidation pattern of 2-(2-aminoethyl)-1-methylpyrrolidine differs from that of udenafil. On the other hand, the oxidation of udenafil resembles those of the alkoxybenzene group and 6-hydroxypurine group of udenafil and 5-(2-ethoxyphenyl)-1-methyl-3-n-propyl-1,6-dihydro-7H-pyrazolo[4,3-d]-7-pyramidinone (EMPP). From the linear relation between the peak current and the concentration of udenafil, square wave (SW) voltammetric method for its determination in udenafil tablets was developed. For analytical purpose, one well-defined diffusion controlled voltammetric peak was obtained in 0.2 M phosphate buffer at pH 2.0. The current-concentration plot was rectilinear over the range of 5×10^−7 to 5×10^−5 M with correlation coefficient of 0.998.
Abstract
The voltammetric behavior of udenafil on glassy carbon electrode was studied using cyclic, linear sweep and square-wave (SW) techniques. Udenafil showed an irreversible oxidation behavior in aqueous buffer solutions containing 30% (v/v) acetonitrile over the pH range of 2 to 6. The oxidation pattern of 2-(2-aminoethyl)-1-methylpyrrolidine differs from that of udenafil. On the other hand, the oxidation of udenafil resembles those of the alkoxybenzene group and 6-hydroxypurine group of udenafil and 5-(2-ethoxyphenyl)-1-methyl-3-n-propyl-1,6-dihydro-7H-pyrazolo[4,3-d]-7-pyramidinone (EMPP). From the linear relation between the peak current and the concentration of udenafil, square wave (SW) voltammetric method for its determination in udenafil tablets was developed. For analytical purpose, one well-defined diffusion controlled voltammetric peak was obtained in 0.2 M phosphate buffer at pH 2.0. The current-concentration plot was rectilinear over the range of 5×10^−7 to 5×10^−5 M with correlation coefficient of 0.998.
참고문헌 (16)
- T. Y. Oh, , Archives of Pharmacal Research, 223(5), pp.471~476 (2000)
- R. C. Kukreja, , Journal of Molecular and Cell Cardiology, 36, pp.165~173 (2004)
- J. R. Fineman, , The American Journal of Physiology, 261, pp.1563~H1569 (1991)
- J. P. J. Halcox, , Journal of the American College of Cardiology, 40(7), pp.1232~1240 (2002)
- J. P. Halcox, , Life Sciences, 78, pp.1211~1216 (2006)
- J. Y. Cho, , Journal of Chromatography B, 795, pp.179~186 (2003)
- J. Rodriguez, , Talanta, 62, pp.427~432 (2004)
- L. Agui, , Anal. Chimi. Acta, 461, pp.65~73 (2002)
- S. A. Ozkan, , Talanta, 61, pp.147~156 (2003)
- B. Uslu, , Anal. Chimi. Acta, 552, pp.127~134 (2005)
- Laviron E., , J. Electroanal. Chemistry, 112, pp.11~ (1980)
- B. Uslu, , Anal. Chimi. Acta, 537, pp.307~313 (2005)
- A. M. Oliveira-Brett, , Bioelectrochemistry, 59, pp.49~56 (2003)
- J. C. Abbar, , Bioelectrochemistry, 83, pp.1~7 (2012)
- C. M. Riley, "Development and Validation of Analytical Methods" (1996), Elsevier
