This study was performed to investigate the quality for microorganisms of water purifiers set up public places used lots of people which in public office, welfare facilities, public bath, school. The water purifiers were installed near the entrance and where they are easily found. None of them were installed at where they should not be installed at the locations stated by law. Heterotrophic plate count at public office, welfare facilities,public bath, school was 0~3,700 CFU/mL, 0~3,400 CFU/mL, 0~3,500 CFU/mL, 0~2,300 CFU/mL respectively. Total coliforms was not detected at public office and school, but found at welfare facilities and public bath. Fecal coliforms was not detected anywhere. The rates bellowing the drinking water quality at public office, welfare facilities, pubic bath, school are 36%, 28.7%, 22.9%, 9.5% respectively. Species of heterotrophic bacteria isolated from public office water purifiers was Micrococcus Luteus, Sphingomonas paucimobilis, Ralstonia mannitolilvtica, Pseudomonas fluorescens etc. Most of bacteria found during the testing are common bacteria that exist in typical living environment.
Abstract
This study was performed to investigate the quality for microorganisms of water purifiers set up public places used lots of people which in public office, welfare facilities, public bath, school. The water purifiers were installed near the entrance and where they are easily found. None of them were installed at where they should not be installed at the locations stated by law. Heterotrophic plate count at public office, welfare facilities,public bath, school was 0~3,700 CFU/mL, 0~3,400 CFU/mL, 0~3,500 CFU/mL, 0~2,300 CFU/mL respectively. Total coliforms was not detected at public office and school, but found at welfare facilities and public bath. Fecal coliforms was not detected anywhere. The rates bellowing the drinking water quality at public office, welfare facilities, pubic bath, school are 36%, 28.7%, 22.9%, 9.5% respectively. Species of heterotrophic bacteria isolated from public office water purifiers was Micrococcus Luteus, Sphingomonas paucimobilis, Ralstonia mannitolilvtica, Pseudomonas fluorescens etc. Most of bacteria found during the testing are common bacteria that exist in typical living environment.
참고문헌 (17)
- 김철호, "수돗물과 정수기 물의미생물학적 수질", 진주산업대논문집, 38, pp.207~214 (1999)
- 김은아, "가정용 정수기의 효율적 이용에 관한 연구", 경기도보건환경연구원보, 16, pp.93~ (2003)
- 정현미, "먹는물 및 먹는샘물중의 미생물 검사", 지구환경논문집, 9, pp.71~88 (1998)
- 이은화, "냉온수기에서 일반세균의 분포 및 분리한 세균의 특성", 미생물학회지, 44(3), pp.244~250 (2008), 한국미생물학회
- Burlingame, G.A., "Bacterial interference with coliform colony sheen production on membrane filters", Applied and Environment Microbiology, 47, pp.56~60 (1984)
- Armas, A.B., "A survey of the microbiological quality of bottled water sold in the UK and changes occurring during storage", International Journal of Food Microbiology, 48, pp.59~65 (1999)
- 서란주, "군산지역 초등학교 정수기 물의 미생물학적 수질", 미생물학회지, 45(1), pp.74~81 (2009), 한국미생물학회
- 홍정하, "학교음용수 관리 및 이용실태", 석사, pp.2001
- Allen, M. J., "Heterotrophic plate count bacteria-what is their significance in drinking water", International Journal of Food Microbiology, 92, pp.265~274 (2004)
- Edberg. S. C., "Virulence and risk from drinking water of heterotrophic plate count bacteria in human population groups", International Journal of Food Microbiology, 92, pp.255~263 (2004)
- 배명숙, "금강호에서 항생제 내성균의 연간 군집 변화에 관한 연구", 석사, pp.2003
- 이성호, "화학적-미생물학적 수질에 대한 강우영향의 특성 (대구지역 약수)", 대한환경공학회지, 24(12), pp.2213~2225 (2002), 대한환경공학회
- 이태관, "계절에 따른 수도와 정수기의 수질비교", 낙동강환경원 환경과학논집, 9, pp.133~137 (2004), 계명대학교
- 이호원, "마산·창원지역 음용수의 미생물오염현황", 24, pp.23~32 (2001), 경남대학교 환경문제연구소
- 현병용, "R", O 정수기 저장용기내의 미생물 검정, 1998, pp.4, 25~30
- 김나영, "초등학교 실내환경에서 공기중 세균과 진균의 분리 및 특성", 미생물학회지, 43(3), pp.193~200 (2007), 한국미생물학회
- 이아미, "학교 실내환경에서 공기중 미생물의 분포 및 특성", 미생물학회지, 41(3), pp.188~194 (2005), 한국미생물학회