How to decide loading capacity is critical to both environmental authority and local government. The former tries to decrease to attain the target water quality and the latter tries to increase the loading capacity to get more development projects. This article aims to establish the rational and mutually agreeable method of calculating loading capacity by presenting to its case in Gwangju City's water pollution load management planning. Gwangju City's loading capacity is 3,012.1 kg/day, which was calculated in both case of using and getting without target water quality in 2007(5.5 mg/L in Suha-Bo).