[PURPOSE] This study is a pilot study to investigate the possibility of kinect sensor based muscle strength test. [METHODS] Ten male subjects (age: 26.30±1.70 years, height: 176.88±2.89cm, weight: 73.40±4.03kg) were selected for the study. The exercise specialist and kinect sensor based muscle strength test program were evaluated at the same time. The items of evaluation were upper strength test (30 sec. arm curls) and lower strength test (30 sec. chair stands). Intraclass correlation coefficient (ICC) was calculated using a two-way mixed model to determine the reliability between the results measured by the exercise instructor and the results measured by the kinect sensor-based muscle strength test method. Bland-Altman plots were used to assess the differences between the two methods and to evaluate the agreement. To obtain the maximum and minimum values of the error intervals, mean + 1.96 × standard deviation and mean -1.96 × standard deviation were calculated. [RESULTS] As a result of upper strength test, ICC was 0.904 (95% CI: .614-.976), Bland-Altman analysis showed that the mean value of the result was 0.6 and the error interval was -3.44 to 4.64. As a result of the test of lower strength test, ICC was found to be 0.895 (95% CI: .576-.974), Bland-Altman analysis showed that the mean value of the result was -0.3 and the error interval was -3.50 to 2.90. [CONCLUSIONS] The ICC of the test showed very high inter - test reliability, showing no difference between the two methods. Therefore, kinect sensor-based muscle strength test may be recommended as a new objective method for testing the strength of the elderly.

Abstract

[PURPOSE] This study is a pilot study to investigate the possibility of kinect sensor based muscle strength test. [METHODS] Ten male subjects (age: 26.30±1.70 years, height: 176.88±2.89cm, weight: 73.40±4.03kg) were selected for the study. The exercise specialist and kinect sensor based muscle strength test program were evaluated at the same time. The items of evaluation were upper strength test (30 sec. arm curls) and lower strength test (30 sec. chair stands). Intraclass correlation coefficient (ICC) was calculated using a two-way mixed model to determine the reliability between the results measured by the exercise instructor and the results measured by the kinect sensor-based muscle strength test method. Bland-Altman plots were used to assess the differences between the two methods and to evaluate the agreement. To obtain the maximum and minimum values of the error intervals, mean + 1.96 × standard deviation and mean -1.96 × standard deviation were calculated. [RESULTS] As a result of upper strength test, ICC was 0.904 (95% CI: .614-.976), Bland-Altman analysis showed that the mean value of the result was 0.6 and the error interval was -3.44 to 4.64. As a result of the test of lower strength test, ICC was found to be 0.895 (95% CI: .576-.974), Bland-Altman analysis showed that the mean value of the result was -0.3 and the error interval was -3.50 to 2.90. [CONCLUSIONS] The ICC of the test showed very high inter - test reliability, showing no difference between the two methods. Therefore, kinect sensor-based muscle strength test may be recommended as a new objective method for testing the strength of the elderly.

참고문헌 (16)

  1. Agmon M, "A pilot study of Wii Fit exergames to improve balance in older adults", Journal of Geriatric Physical Therapy, 34(4), pp.161~167 (2011)
  2. Clark R, "Clinical use of Nintendo Wii bowling simulation to decrease fall risk in an elderly resident of a nursing home : a case report", Journal of Geriatric Physical Therapy, 32(4), pp.174~180 (2009)
  3. Douris P. C, "Comparison between Nintendo Wii Fit aerobics and traditional aerobic exercise in sedentary young adults", Journal of Strength & Conditioning Research, 26(4), pp.1052~1057 (2012)
  4. Fleiss J. L, "Analysis of data from multiclinic trials", Control of Clinical Trials, 7, pp.267~275 (1986)
  5. Garcia J. A, "Exergames for the elderly: towards an embedded Kinect-based clinical test of falls risk", Stud Health Technol Inform, 178, pp.51~57 (2012)
  6. Guralnik J. M, "Lower extremity function and subsequent disability:consistency across studies, predictive models, and value of gait speed alone compared with the short physical performance battery", The journals of gerontology. Series A, Biological sciences and medical sciences, 55, pp.M221~M231 (2000)
  7. Kannus P, "Prevention of falls and consequent injuries in elderly people", Lancet, 366(9500), pp.1885~1893 (2005)
  8. Keith N. R, "Developing a self-reported physical fitness survey", Medicine and Science in Sports and Exercise, 44(7), pp.1388~1394 (2012)
  9. Kim H. S, "Senior Fitness Test Manual" (2014), Deahanmedia
  10. Kim J. K, "Human posture recognition using Kinect sensor", The Korean Institute of Electrical Engineers, 7, pp.1371~1372 (2012)
  11. Rikli R. E, "Senior fitness test manual", pp.161~ (2001), Human Kinetics
  12. Rikli R. E, "Functional fitness normative scores for community-residing older adults ages 60-90", Journal of Aging and Physical Activity, 7(2), pp.162~181 (1999)
  13. Rosenberg I. H, "Sarcopenia: origins and clinical relevance", Journal of Nutrition, 127(5Suppl), pp.990S~991S (1997)
  14. Schilke J. M, "Slowing the aging process with physical activity", Journal of Gerontological Nursing, 17(6), pp.4~8 (1991)
  15. "Statistics on the aged" (2015)[URL]
  16. Zamboni M, "Sarcopenic obesity: a new category of obesity in the elderly", Nutrition, Metabolism and Cardiovascular Diseases, 18, pp.388~395 (2008)

관련 논문AI추천